Protocol Specs
- 20 -
COMMAND
PARAMETER
function example
PV
OFF
Picture Mode
=OFF
PV
OFF
<CR>
STD
Picture Mode
=STANDARD
PV
STD
<CR>
MOV
Picture Mode
=MOVIE
PV
MOV
<CR>
VVD
Picture Mode
=VIVID
PV
VVD
<CR>
STM
Picture Mode
=STREAM
PV
STM
<CR>
CTM
Picture Mode
=CUSTOM
PV
CTM
<CR>
?
Return P
V Status
PV
?
<CR>
CN UP CONTRAST UP/DOWN , direct change to **dB PVCN UP<CR>
CN DOWN **:44 to 56 by ASCII , 50=0 PVCN DOWN<CR>
CN ** --- AVR-X2000/E400 can be operated from -6 to +6(44 to 56)
PVCN 50<CR>
CN ? Return PVCN Status PVCN ?<CR>
BR UP BRIGHTNESS UP/DOWN , direct change to **dB PVBR UP<CR>
BR DOWN **:00 to 12 by ASCII , 00=0 PVBR DOWN<CR>
BR ** --- AVR-X2000/E400 can be operated from 0 to 12 PVBR 12<CR>
BR ? Return PVBR Status PVBR ?<CR>
ST
UP
Saturation
UP/DOWN , direct change
to **dB
PVST
UP<CR>
ST
DOWN
**:44 to 56 by ASCII , 50=0
PVST
DOWN<CR>
ST
**
---
AVR
-
X2000/E400
can be operated from
-
6
to
+6(44 to 56)
PVST
50<CR>
ST
?
Return PVST Status
PVST
?<CR>
HUE UP HUE UP/DOWN , direct change to **dB PVHUE UP<CR>
HUE DOWN **:44 to 56 by ASCII , 50=0 PVHUE DOWN<CR>
HUE ** --- AVR-X2000/E400 can be operated from -6 to +6(44 to 56)
PVHUE 50<CR>
HUE ? Return PVHUE Status PVHUE ?<CR>
DNR OFF DNR direct change PVDNR OFF<CR>
DNR LOW PVDNR LOW<CR>
DNR MID PVDNR MID<CR>
DNR HI PVDNR HI<CR>
DNR ? Return PVDNR Status PVDNR ?<CR>
ENH UP ENHANCER UP/DOWN, direct change to **dB PVENH UP<CR>
ENH DOWN **:00 to 12 by ASCII, 00=0 PVENH DOWN<CR>
ENH ** --- AVR-X2000/E400 can be operated from 0 to 12 PVENH 12<CR>
ENH ? Return PVENH Status PVENH ?<CR>
PV COMMAND : "*" parameter uses two ASCII characters. (see page6 J) section)