Owner's Manual

173
Appendix
TipsPlaybackConnections
Contents
Front panel Display Rear panel IndexRemote
Settings
2 About Setup and measurement microphone
placement
•Measurements are performed by placing the Setup and measurement
microphone successively at multiple positions throughout the entire
listening area, as shown in GExample qH.
•Even if the listening environment is small as shown in GExample wH,
measuring at multiple points throughout the listening environment
results in more eective correction.
FL SW C FR
SRSL
*
M
FL SW C FR
SRSL
*
M
(
: Measuring positions)
GExample qH GExample wH
(
: Measuring positions)
FL Front speaker (L) SW Subwoofer
FR Front speaker (R) SL Surround speaker (L)
C Center speaker SR Surround speaker (R)
2 About the main listening position (*M)
The main listening position is the position where listeners would
normally sit or where one would normally sit alone within the listening
environment. Before starting Audyssey® Setup, place the Setup and
measurement microphone in the main listening position. Audyssey
MultEQ® XT32 uses the measurements from this position to calculate
speaker distance, level, polarity, and the optimum crossover value for
the subwoofer.
2 About Audyssey Sub EQ HT™
Audyssey Sub EQ HT™ makes the integration of dual subwoofers
seamless by first compensating for any level and delay dierences
between the two subwoofers and then applying Audyssey MultEQ®
XT32 to both subwoofers together.
To run Audyssey Sub EQ HT™ you must select “Measure (2 spkrs)” in
“Channel Select” (vpage175).