User Guide
17
POA-3012CI
TROUBLE SHOOTING
NO
NO
Disconnection of T101 or trouble of D101-104.
YES
YES
YES
FLOW CHART NO.1
The power cannot be turned on.
(Power indication LED dose not light)
Is the voltage of 6V supplied to C147?
Is the voltage of 4V supplied to C150?
Trouble of IC104.
NO
Trouble of IC701.
Is the voltage of Hi (3.3V) output to 19 pins and 20 pins
of the microprocessor (IC701)?
Trouble of LED(LD707).
NO
NO
Trouble of IC701 and TR101-TR104.
YES
YES
FLOW CHART NO.2
Power is turned on, but FLD does not light.
Is 6V supplied to the coil of power supply relay RL101
and 102?
Are fuse (F101, 102, 107, 109) normal?
Trouble of the transformer.
The power supply circuit of FLD or trouble of FL701.
Trouble of communication unit.
FLOW CHART NO.4
Using the PC, setting is not possible.
The screen of the setting is not displayed to the PC.
Trouble of power circuit or temperature
detector.
FLOW CHART NO.3
Power is turned on and FLD lights up, but sound is not output.
When all zone operation mode LED
flashes in red.
When
zone operation mode LED
which
the sound does not produce flashes in
red.
Trouble of the power amplifier unit of
ZONE flashing in red.
Trouble of input unit or audio
signal unit.
When Zone operation mode LED
lights normally.
(Green or an orange)
トラブルシューティング
いいえ
いいえ
T101の断線またはD101-104の故障
はい
はい
はい
フローチャート NO.1
電源が入らない。(電源表示LEDが点灯しない)
C147に6Vの電圧が供給されているか?
C150に4Vの電圧が供給されているか?
IC104の故障
いいえ
IC701の故障
マイコン(IC701)の19ピンと20ピンにHi(3.3V)
の電圧が出力されているか?
LED(LD707)の故障
いいえ
いいえ
IC701またはTR101-TR104の故障
はい
はい
フローチャート NO.2
電源は入るがFLDが点灯しない。
電源リレーRL101、102のコイルに6Vが供給されている
か?
ヒューズ(F101、102、107、109)は正常か?
トランスの故障
FLD電源回路またはFL701の故障
通信ユニットの故障
フローチャート NO.4
パソコンを使って設定ができない。
パソコンに設定画面が表示できない。
電源回路または温度検出回路の故障
フローチャート NO.3
電源は入りFLDは点灯するが音が出ない。
ZONEの動作表示LEDが6個全て赤点滅
音の出ないZONEの動作表示LEDが赤点滅
赤点滅ZONEのパワーアンプユニットの
故障
インプットユニットまたはオー
ディオシグナルユニットの故障
ZONEの動作表示LEDは通常どおり
(緑または橙点灯)