[4.1] Setting an auto-start execution program
On the SET SYSTEM menu, selecting "1: EXECUTE PROGRAM"
calls up the screen shown at left.
Highlighted is the current setting.
Use the F5 and F6 keys to move the cursor to a desired execution
program to be run automatically when the power is applied, and then
press the ENT key.
To return to the SET SYSTEM menu, press the C key.
If no program files are stored in the memory, the screen shown at left
will appear.
To return to the SET SYSTEM menu, press the C key.
[4.2] Setting the message version, system status indication, and BHT-5000 screen
compatibility mode
On the SET SYSTEM menu, selecting "2: DISPLAY" calls up the
screen shown at left.
Highlighted is the current setting.
[1] MESSAGE: Switches the message version to English o
r
Japanese for system error messages and
indications on the LCD contrast, beeper volume,
beeper & vibrator switching, and battery voltage
level screens. (The default is the message version
that you selected in the initializing sequence.)
[2] STATUS: Turns the system status indication on or off. Setting
this to ON displays the shift state of the keys,
alphabet entry mode and communications link with
the CU-311, using the icons shown on the next
page.
[3] BHT-5000: Turns the BHT-5000 screen compatibility mode on
or off. (See the next page.)
Select a desired item by using the numerical keys or F5 and F6 keys,
then select a desired setting by using the F7 and F8 keys.
Press the ENT key.
To return to the SET SYSTEM menu, press the C key.
You can turn the system status indication on or off also by using
the OUT statement in user programs. Refer to the "BHT-BASIC
Programmer's Manual."
54