Specifications

180
Chapter 9 Vision Manager
9.2.13.1 Specifying measurement conditions
Automatic digitization
Enable or disable automatic digitization. Choosing True specifies automatic digitization.
Digitization thresholds
If automatic digitization has been disabled, these two fields specify the two boundaries used in digitization.
9.2.13.2 Reading in a QR Code symbol
Operating procedure
1. Choose a target window range to measure.
2. Enable or disable automatic digitization.
Choose True for automatic digitization. Otherwise, specify the thresholds with the Register digitization set-
tings screen.
3. Press the Measure button to display the resulting boundaries on the histogram, save them
in the two boundary fields of the Digitization settings screen, and display the results in the
Vision monitor window.