Specifications
Chapter 9 Operating Vision Manager
9-21
9.4.1.1 Look-up Table
Click the Look Up tab to set the lookup table characteristics. By changing the
lookup table the user can change the camera image input characteristics,
camera images and processing screen display characteristics. 0 to 4, in the
lookup table, are reserved by the system. 5 to 15, in the lookup table, can be
changed by general users.
Graphic display of characteristics
Q Drag scroll bar (A) to display the table of
characteristics in the list (B).
R Click the column (C) in the table to display
characteristics.
In this example, the graph (D) shows the
characteristics of Table 7.
Input and edit of set value numerals
Q Double-click the cell (E) to change the set
value.
The cell character is displayed in reversal.
R The input character will then be input
(inserted) in the position in the reversed
character.
Copy a standard table
Q Click the column (F) in the table to copy the
standard table.
R Select the standard table (G).
S Click on Set to Standard (H).
The standard table is copied into the selected
table. In this example, 100% is copied to
Table 5.
Save editing results
Click OK to save the set value.
To invalidate the editing results, click Cancel.
G
E
D
C
A
B
H
G
F