Specifications
Chapter 9 Operating Vision Manager
9-23
(3) Synchronous method
Set the synchronous method in the camera. Since all the cameras are
simultaneously set, it is not possible to discretely change the camera
settings. For internal synchronization, set camera input with the Vision
Board internal synchronous signal. For external synchronization, set
camera input with the camera synchronous signal.
0: Camera internal synchronization 1: Camera external synchronization
(4) SHCORNER setting
Set the SHCORNER command measuring conditions. For details of each
parameter (distance, intervals, width and height), refer to SHDEFCORNER
command.
(5) SHCIRCLE setting
Set the SHCIRCLE command measuring conditions. For details of each
parameter (intervals and width), refer to SHDEFCIRCLE command.
(6) Search time-out time
Set the timeout time for search measurements (SHMODEL command,
SHCORNER command and SHCIRCLE command).
Search measurement error is detected by timeout.
(7) Vision monitor display position
Set the display position with the processing screens (0 to 2) displayed on
the Vision Monitor.
0: Center 1: Left 2: Right
(8) Search compatible mode
Set the kind of search models to be registered.
The search models are classified into two kinds: search mode that does not
require angle measurement and the model that requires angle
measurement. This setting allows you to choose the model kind for
registration. If you select “1” or ”2”, the models that can be registered with
one model number to limited to one kind; thereby, you can increase the
number of models that you can register.
1: Model that does not require angle measurement
2: Model that requires angle measurement
3: Both