9-52
[ 4 ] Binary Process Registration Screen
Converts the specified range of the currently displayed processing screen to
the binary codes.
Binary process registration tool Q Display the processing screen to be binary-coded
on the vision monitor by using the monitor display.
R Click on
in the tool bar.
The Binary Process Registration window appears.
S Select a window for specifying the binary-coding
range at Process Range (A).
T Click on Execute.
The specified range of the processing screen is
binary-coded.
[ 5 ] Detecting Binary-coded Level
Automatically detect the binary-coded level of the processing screen currently
on display.
Binary process registration tool Q Display a processing screen where you want to
detect the binary-coded level using the monitor
display tool.
R Click on
in the tool bar.
The Binary Process Registration window appears.
S Select a window for detecting binary-coded level
with processing range (A).
T Set detection mode (B) to auto (mode method,
discriminant analysis method and P tile method).
For detection mode other than P tile method,
proceed with step after W.
U Specify the reference area (C) to use for the P tile
method.
V Specify the object area (D) to measure with the P
tile method.
W Click on Detect Level.
The histogram appears.
Displays the detected binary-coded level at (E).
- Result of binary-coding -
Before binary
codin
g
After binary
codin
g
A
BE DC
A