[ 2 ] Model Search Measuring
Model search measure tool
Q Model search measure tool in the tool bar.
The Model Search window appears.
The window shape appears on both the teaching
panel and the vision monitor.
R Select Object Window (A).
The specified window range will be the object for
measuring.
S Select Search Model (B).
T Specify Coincidence (C).
U Select Detection unit (D) from Pixel or Sub-pixel.
V Specify Detection number (E).
W Specify Start Angle (F).
X Specify End Angle (G).
Y Click on Execute.
The Vision Manager measures the currently
selected processing screen and displays the results
in the Result table (H).
The processing results appear on the vision
monitor.
- Measurement result -