WDR-516S Installation Guide
FCC Compliance Statement Caution : Any changes or modifications in construction of this device which are not expressly approved the party responsible for compliance could void the user's authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Important Notice 1. Do not place heavy objects on the top of the WDR-516S. 2. WDR-516S is not weatherproof. In case of outdoor use, equip a weatherproof case to protect WDR516S from water, moisture, or temperature (higher or lower than specifications). To clean the WDR-516S, gently wipe the outside with a clean dry cloth. 3. Be sure to use a DC adapter that is provided by DENTEC Corp. Connecting WDR-516S directly to an AC current will cause electric damages to WDR-516S. 4.
OVERVIEW.................................................................................................................................. 7 1. What is WDR-516S?............................................................................................................ 7 2. Supplied Accessories......................................................................................................... 8 3. Description & Function ..............................................................................
8.2.2. Daylight Saving..................................................................................................... 22 8.2.3. Time Format ......................................................................................................... 23 8.2.4. Date ...................................................................................................................... 23 8.2.5. Time.........................................................................................................
14.3. Available HDD.......................................................................................................... 36 14.4. Registering & Formatting HDD................................................................................. 37 15. Network Monitoring & Managing ................................................................................. 38 15.1. Connecting Ethernet ................................................................................................ 38 15.2.
OVERVIEW 1. What is WDR-516S? The WDR-516S is a 4-Analog, 12-IP channel network digital video recorder. The WDR-516S can record and display 4 analog video channels and 12 IP video channels simultaneously. Video, Audio, and Text Event-Logs are digitized and stored on two internal hard-drives.
2. Supplied Accessories Unpack and check all the items as below. 1. WDR-516S (1) 2. DC Power Supply (1) (110V~220V) 3. AC Power Cord (1) 4. CD-ROM (Including WDR Manager) (1) 5. Remote Controller (1) 6. Guide (2) 7. Plug Bracket (1) 8. HDD Fixing Screw (8) WDR-516S Installation Guide 8 Rev 1.
3. Description & Function WDR-516S Front 1 3 6 4 2 5 (1) LED (2) IEEE1394 connecter (3) Remote controller receiver (4) USB connecter (5) Function buttons (6) Bracket fixing hole for rack mount WDR-516S Installation Guide 9 Rev 1.
WDR-516S Rear 10 11 9 7 8 13 14 12 15 19 16 17 18 20 (7) Power switch (8) Ethernet connector (9) BNC connector for Video input (10) Audio input / output connector (11) RS232 connecter (9Pin D-Sub) (12) Terminal block for RS232 & 422/485 (13) Terminal block for Sensor input (14) Terminal block for Relay output (15) Video output for MONITOR or VCR (16) Video input type/impedance select & remote controller switch (17) IEEE1394 connecter (18) USB connecter (19) Power connector (DC12V) (20) GND WDR-
INSTALLATION AND CONNECTION 4. Connecting & Running WDR-516S 4.1. Connecting camera (1) Connect CCTV camera to WDR-516S with BNC cable as shown below. (2) Set video type (NTSC/PAL) by rear panel’s switch. The video type for all channels should be either NTSC or PAL. NTSC is the standard used in North America. (3) Set the impedance control switch for each channel as needed. It may be necessary to configure impedance of video input differently for each channel.
4.2. Connecting Monitor (1) Connect CCTV monitor to WDR-516S with BNC cable as shown below. WDR-516S has two video output ports ; for Monitor and VCR. The output signals from the two ports are same and either port may be used. 4.3. Connecting Audio (1) Connect audio signal to WDR-516S. WDR-516S Installation Guide 12 Rev 1.
4.4. Supplying Power (1) Connect power cable to WDR-516S. (2) Turn on the power switch located on the WDR-516S rear panel. Use the plug bracket to secure the power cable if needed. To connect EARTH, refer to the following picture. WDR-516S Installation Guide 13 Rev 1.
5. Running OSD menu 5.1. Using menu Press the [MENU] button to open the OSD Configuration Menu. (1) Main Menu (2) Sub-menu (3) Setting Page (4) Help message (1) Main Menu Tabs: The selected tab is shown in blue and the related sub-menus will be shown below the tab. To move to the previous/next Main Menu Tab, use the [◄ or ►] arrow buttons. To move to a sub-menu, press the [ENTER] or [▼] buttons.
5.2. Dialogue Box to Edit a Word There are two methods to set word. (1) Using number button Enter the related numbers in order of horizontal/vertical. (For example, in order to select “ C ” , press [3] and [2] buttons.) (2) Using arrow button Select a value using the [◄ or ►] or [▲/▼] buttons. The intersection of the horizontal and vertical bar is selected value. Press the [►] button to confirm the selected value.
6. Setting remote controller 6.1. Setting remote control DIP switch Set the remote control DIP switch to “ON.” REMOTE CONTROL Hi-Z N ON 1 2 3 4 P OFF 6.2. Set ID of WDR-516S When controlling several WDR-516S with one remote controller, set Remote Control ID as follows. (1) Press [MENU] button. (2) Select “System” with using [►] button and press the [ENETR] or [▼] button. WDR-516S Installation Guide 16 Rev 1.
(3) Select “Miscellaneous” from the sub-menu list using the [▼] button and press the [ENETR] button. (4) Select “Remote Control ID,” and press the [ENETR] button. (5) Select a value using the [◄ or ►] buttons and press the [EXIT] button. (6) Press the [EXIT] button to exit the Settings Page and return to Monitor mode. Remote Control ID Up to 16 WDRs can be controlled with a single remote controller. 6.3.
6.4. Operable range of remote controller WDR 6.5. Loading the batteries into remote controller Remote controller requires two AAA-type batteries. 1. Remove the battery cover. WDR-516S Installation Guide 2. Taking care that the poles(+/-) are correctly positioned. 18 3. Replace the battery cover. Rev 1.
7. WDR-516S Configuration 7.1. Basic Configuration 7.2. Advanced Configuration WDR-516S Installation Guide 19 Rev 1.
7.3. External Storage & Backup Configuration 7.4. Internet/Intranet Configuration WDR WDR-516S Installation Guide 20 Rev 1.
8. WDR-516S Basic Setting 8.1. Viewing Image After initial start-up, images from Ch.1~4 are displayed in a quad-split screen. If user password is set, a prompt for entering the password will appear. WDR-516S Installation Guide 21 Rev 1.
8.2. Setting Date & Time (1) Press [MENU] button, and select “Quick Setup” tab. (2) Select “Date/Time” and enter the Settings Page by pressing [ENTER]. 8.2.1. Time Zone (1) Select “Time Zone” and press [ENETR] button to configure. (2) Select a value using the [◄ or ►] button and press the [EXIT] button when finished. 8.2.2. Daylight Saving (1) “Daylight Saving Time” is only activated for time zones that use Daylight Savings. If activated, press [ENTER] to enter a new value.
8.2.3. Time Format (1) Select “Time Format” using the [◄ or ►] or the [▲/▼] buttons and press [ENTER]. (2) Two Time Formats are available; ‘MM/DD/YYYY’ and ‘YYYY/MM/DD’. Select a value using [▲/ ▼] buttons, and press the [EXIT] button when finished. (Default value is ‘MM/DD/YYYY’.) 8.2.4. Date (1) Select “Date” using the [◄ or ►] or the [▲/▼] buttons and press [ENTER]. (2) Select ‘MM’/‘DD’/‘YYYY’ using the [◄ or ►] buttons, and select the value using the [▲/▼] buttons.
8.3. Setting Recording Condition Recording conditions under the “Quick Setup” menu tab apply the same values to all analog channels 1~4. All settings are applied for 24 hours/day regardless of the values set for “Time Schedule” or “Alarm Rec.” WDR-516S Installation Guide 24 Rev 1.
(1) Press [MENU] button, and select “Quick Setup.” (2) Move to sub-menu by pressing [ENTER] or the [▼] button. (3) Select “Recording” using the [▲/▼] buttons and press the [ENTER] button. 8.3.1. Configuration Status Displays the recording configuration status. When setting up through the “Quick Setup” menu, “Quick Setup” will be shown. When setting up through “Normal Rec.” or “Alarm Rec.,” “Custom Setup” will be shown.
8.3.5. Quality When “Recording Speed/Quality” is set as “Custom,” values can be set manually. (1) Select “Quality” using [▲/▼] buttons and press the [ENTER] button. (2) Select a value using the [◄ or ►] button. Press the [EXIT] button when finished. 8.3.6. Audio Recording (1) Select “Audio Recording” using [▲/▼] buttons and press the [ENTER] button. (2) Select a value using the [◄ or ►] button. Press the [EXIT] button when finished. 8.3.7.
9. Connecting and Configuring Sensor 9.1. Connecting Sensor Input To connect a sensor to S1, fix the wire to “S1” and “G“. S1 G Devices connected to the sensor input should have “Dry contact.” The following diagram is of an electric circuit with approximately 12mA flows. WDR-516S Installation Guide 27 Rev 1.
9.2. Setting Sensor at OSD menu After a sensor is connected, it can be activated through the OSD Configuration menu. Select the sensor number (S1, S2, etc.) and press the [Enter] button to configure. Use the [◄ or ►] buttons to select “On” or “Off.” Press [EXIT] when finished. When activated, the “Pre / Post Alarm” function will cause the WDR-516S to record images at the specified Speed and Quality for a length of time before and/or after the sensor is triggered.
10. Connecting & Configuring Relay Out 10.1. Connecting Relay Out WDR-516S has total four ports of Relay Out. To connect a device to “R1,” connect the wires to two “R1”s. R1 R1 The rated voltage and current of Relay Out are as follows. Do not exceed the rated values. 24V Maximum Switching Capacity DC, 1.25A, 30W 125V DC, 0.24A, 30W 125V AC, 0.5A, 62.5VA WDR-516S Installation Guide 29 Rev 1.
10.2. Configuring Relay Out Each relay can be synchronized with a sensor input or with motion detection for each of the four time sch edules (Weekday (Day), Weekday (Night), Weekend (Day), Weekend (Night)). Relays can also be control led locally by pressing the [SEARCH/RELAY] button followed by the relay number (14). Relays can also be controlled remotely through the “WDR Manager S/W.” WDR-516S Installation Guide 30 Rev 1.
11. Connecting External Device with Serial Port 11.1. Connecting Text Input Device (ATM / POS / Access Control) In addition to images, the WDR-516S can record text data received from POS/ATM through the RS232 serial port. Connect RS232 to 9pin D-sub of WDR-516S, and configure the “Text” sub-menu under the “System” tab. Set “Serial Setup” under the “System” menu tab to “RS232” and “Device” to “Text.” The baud rate may d iffer for each device; consult the device manual for more information.
12. Connecting & Configuring Serial Ports for Pan/Tilt/Zoom 12.1. Connecting Serial Port The WDR-516S has most major PTZ protocols already pre-programmed. Makes and models not supported can still be controlled using the Transparent Protocol. For a list of supported protocols, refer to the list on the OSD Configuration menu. 12.1.1. Connecting RS232 Fix the wire to 1~3 pins (RX, TX, GND). GN TXD RXD 12.1.2. Connecting RS485 Fix the wire to 4~5 pins and 8 pin (R+, R-,GND). GND R+ R- 12.1.3.
12.2. Configuring Serial Port Configure PTZ serial ports and available modes at “System / Serial Setup”. After completing serial setup, configure base address and port for each channel under the “Camera” menu tab. When connecting PTZ devices to several cameras, be sure the base address matches the address for the camera. WDR-516S Installation Guide 33 Rev 1.
Wire Handling Trimming Wire When connecting a wire to a terminal block, follow the instructions below. Note the different types of wire that can be used. Stranded Wire: Peel off the wiring cover 8~10mm and solder it. Wire gage should be AWG 22 ~ 26. Solid Wire: Peel off the wiring cover 8~10mm and solder it. Wire gage should be AWG 20 ~ 26. Inserting & removing wire To insert the wire, use a screwdriver as shown in the diagram to the right. 13.
If properly connected, the disk is recognized automatically as in the following picture. To copy images, the process is as follows: Set copy range (up to 1 minute) Æ Select drive Æ Copy (press “Start”). USB Flash products that require a Windows program to operate may not be recognized by the WDR516S. WDR-516S Installation Guide 35 Rev 1.
14. Connecting External Storage 14.1. IEEE1394 Bay WDR-516S has three IEEE1394 ports for external storage device interface. With them, WDR-516S can expand storage capacity up to 4TB. Some IEEE1394 Bay may not be recognized by the WDR-516S. Before purchasing, consult the local DENTEC distributor. 14.2. Connecting IEEE1394 Device When using FireWire supported external HDD, hard drive bays can be connected to 1 port in the front panel or 2 ports in the rear panel.
14.4. Registering & Formatting HDD “Disk Manager” will automatically run on start-up after installing a HDD. If “Disk Manager” does not automatically run on start-up, make sure the HDD is properly installed. (1) Press [ENTER] button at “Select Disk”. (2) Select new added HDD (indicated as “[F]”) using [▲/▼] button and press [EXIT] button (3) Select “Action” using [▲/▼] button and press [EXIT] button. (4) Select “Add” using [◄ or ►] button and press [EXIT] button.
(8) Select “Apply” using [▲/▼] button and press [EXIT] button. The HDD status is changed to “[R]” after formatting. (9) Shut down “Disk Manager” by pressing [EXIT] button. 15. Network Monitoring & Managing WDR-516S can be accessed, controlled, and managed from remote site via Internet/Intranet. 15.1. Connecting Ethernet 1) Turn off WDR-516S’s power switch. 2) Connect WDR-516S to hub with Ethernet cable. 3) Turn on WDR-516S’s power switch. 1.
15.2. Configuring WDR-516S’s Network Information The following description is on based on Ethernet connection. For more detailed information on the Network Settings Page, please refer to “WDR-516S OSD User’s Guide”. (1) Press [MENU] button. (2) Select “System” using the [◄ or ►] buttons and press [ENTER]. (3) Select “Network” using the [▲/▼] buttons and press [ENTER]. (4) Select “IP Addr” using the [▲/▼] buttons and press [ENTER]. (5) Press [EXIT] button after entering IP address in the dialogue box.
16. Using WDR Manager 16.1. PC System Requirements for running WDR Manager Minimal Requirements Recommended Requirements CPU P-Ⅲ 600MHz or above P-Ⅲ 1GHz or above RAM 128 MB or above 256 MB or above VGA 16 MB or above 32 MB or above OS Windows 2000/XP Windows 2000/XP Resolution 1024 X 768 pixels or above 1024 X 768 pixels or above Network 100 Base TX Fast Ethernet 100 Base TX Fast Ethernet 16.1.1.
(4) Select which components to install and press the “Next” button. (5) Browse and choose a directory if the default directory is not preferred. Click the “Install” button, after selecting a directory to install. (6) Click the “Close” button after WDR Manager program is installed successfully WDR-516S Installation Guide 41 Rev 1.
16.1.2. Uninstalling WDR Manager (1) Click Windows “Start” Button. (2) Select and Click ‘Uninstall’ icon to run Uninstall Shield. (3) WDR Manager program will be automatically deleted. 16.2. Configstation Click icon on desktop to run “WDR Manager Configstation” program. WDR-516S Installation Guide 42 Rev 1.
16.3. Monitor Click the related icon and run the “WDR Manager Monitor” program. 16.4. Playback Click the related icon and run the “WDR Manager Playback” program. WDR-516S Installation Guide 43 Rev 1.
APPENDIX APPENDIX WDR-516S Installation Guide 44 Rev 1.
Appendix #1 Installing and Replacing internal HDD Compatible HDD It is recommended to use the following HDD models with the WDR-516S. If a non-recommended HDD is used, DENTEC Corp. will not guarantee the warranty. Manufacturer : MAXTOR Series DiamondMax Plus 9 (7200rpm) Model No. Size 6Y060L0 60GB 6Y080L(P)0 80GB 6Y120L(P)0 120GB 6Y160L(P)0 160GB 6Y200P0 200GB 6Y250P0 250GB Series DiamondMax 16 (5400rpm) Model No.
The dip switch should be set at ‘MASTER’ position for the first installed or built-in HDD. Additional HDD should be set as ‘SLAVE.’ Identical dip switch setting may cause system conflict or mal-function. (3) Remove the 6 screws as illustrated below and pull up the cover from the rear part to open SCREW 6EA TOP COVER (4) Take out power and data cable of HDD from Main PCB ASS’Y. Remove 4 HDD Bracket screws and take out HDD ASS’Y.
(5) Fix the HDD with provided screws. Connect power and data cables to HDD MASTER HDD HDD POWER CONNECTOR SLAVE HDD HDD FIXING SCREW 4EA HDD FIXING SCREW 4EA HDD POWER CONNECTOR Installing single HDD Installing 2 HDDs Caution for HDD Management 1. Replacing ‘SLAVE’ HDD of internal 2 HDDs causes permanent data loss in the SLAVE HDD. 2. MASTER HDD has all the index of stored data including ‘SLAVE’ HDD. Corruption on ‘MASTER’ HDD may cause total data loss. Be careful when handling the main HDD.
HDD CABLE (8) Assemble the top cover. Registering & Formatting HDD “Disk Manager” will automatically run on start-up after installing a HDD. If “Disk Manager” does not automatically run on start-up, make sure the HDD is properly installed. (9) Press [ENTER] button at “Select Disk”. (10) Select new added HDD (indicated as “[F]”) using [▲/▼] button and press [EXIT] button WDR-516S Installation Guide 48 Rev 1.
(11) Select “Action” using [▲/▼] button and press [EXIT] button. (12) Select “Add” using [◄ or ►] button and press [EXIT] button. (13) Select “Apply” using [▲/▼] button and press [EXIT] button. The HDD status is changed to “[*]”. (14) Select “Action” using [▲/▼] button and press [EXIT] button. (15) Select “Format” using [◄ or ►] button and press [EXIT] button. (16) Select “Apply” using [▲/▼] button and press [EXIT] button. The HDD status is changed to “[R]” after formatting.
Appendix #2 Video Input Video type / impedance setup switch It’s possible to set up Impedance of Video input line. When one Video output is connected to several Input as below, the impedance of one input should be 75 ohm. REMOTE CONTROL Hi-Z N ON 1 2 3 4 P OFF WDR-516S Installation Guide 50 Rev 1.
Appendix #3 Using CD-ROM Components of CD- ROM disc Installation Guide : WDR-516S Installation Guide User’s Guide : WDR-516S User’s Guide WDR Manager : WDR Manager User’s Guide ( WDR-516S Remote Management Program) Preparation To read manual of CD-ROM disc, Adobe Acrobat 5.0 should be installed in client’s PC. Reading manual of CD-ROM Follow the steps to read user’s guide. 1. Insert the supplied CD-ROM into CD-ROM drive of PC. 2. Open the user’s guide, PDF file.
Appendix #4 Specification General CPU 32bit RISC Processor (200MIPS) Flash Memory 8MB Main Memory 64MB OS Embedded LINUX Video Channel 4 Analog Channel & 12 IP Video Channel (NTSC or PAL) Storage Device Internal 3.5” IDE HDD 2EA External 3EA for IEEE1394 Interface Support Max.
Display Monitoring Max. 120ips (Analog Video 60ips) (IP Video 60ips) Viewer 1ch, 4ch, 9ch, 13ch, 16ch, Auto Sequential Playback Performance Max.
PTZ Control Serial Port RS232(1), RS485/422(1), RS232(1) Control Method (Local) Front panel button & IR remote controller (control IP video channel as well) Control Method (Remote) On-the-screen PTZ control on PC Preset Mode 16 points preset per channel Others Digital Zoom 2x (Live & PlayBack Mode) Alarm Trigger Motion Detection or Sensor input Alarm Data Preservation Alarm triggered Video Data Preservation Alarm Log Log search Log monitoring via OSD & Network Pre/Post Alarm Pre : 1~10 seco
Mechanical Dimension (WⅹDⅹH) 350ⅹ298ⅹ66(mm) Weight 3.5Kg (With one HDD) RS-232 COMM.
Model: WDR-516S Warranty: Full 1 year as of invoice shipping date Manufacture :DENTEC CORP. Email: tech@dentec.com.tw Address: 8/F, No. 116 Hou-Kang St. Shih-Lin Dist, Taipei, Taiwan http://www.dentec.com.tw WDR-516S Installation Guide 56 Rev 1.