Installation guide

137
4%%"%*E-//7'-/*
Listed below are error or warning messages and the steps to resolve the error.
!
!
!
!
!
!
Error Message
Solution
A!project!with!that!name!already!exists!
at!the!specified!location.!Do!you!want!to!
overwrite!the!file?!!
You!have!attempted!to!create!a!project!with!a!name!
that!matches!an!existing !project!in!the !sam e!
directory.!Click!Yes!if!you!wish!to!overwrite!the!file.!!
An!auto!EQ!could!not!be!set.!Try!varying!
the!autoset!param eters!!
You!have!specified!parameters!for!the!auto!EQ!that!
collectively!could!not!be!achieved.!Try!changing!the!
boost,!cut,!range!or!number!of!sliders.!!
An!error!occurred!executing!the!above!
actions.!!
This!is!a!general!error!message.!If!the!error!recurs,!
contact!DEQX.!!
An!error!occurred!when!adding!the!
measurement!to!the!speakers!collection.!!
Project!file!is!probably!corrupted!&!try!creating!a!
new!one,!or!right&click!on!the!project!and!select!
'Save!an d !C o mpress!Project!A s...'.!!
An!error!occurred!while!processing!the!
measurement.!!
Repeat!the!measurement.!If!the!error!recurs,!
contact!DEQX.!!
An!error!occurred!whilst!trying!to!save!
the!filters!!
1.!This!may!occur!due!to!communication!problems!
between!the!PC!and!the!PDC.!Turn!the!PDC!off!then!
on!again!(using!the!power!switch!at!the!back!of!the!
PDC)!and!try!again.!If!this!does!not!restore!
communications,!turn!the!PDC!off!using!the!back!
switch,!then,!whilst!holding!down!the!P3!button!on!
the!front!panel,!turn!the!PDC !back !on!aga in.!2.!This!
also!occurs!for!most!errors!whilst!generating!the!
filters!for!PDC !con fig u ra tio n s.!T o!work!out!what!it!
is,!try!a!‘simpler’!PDC !configuration,!or!one!that!is!
known!to!work.!If!the!error!cannot!be!eliminated,!
contact!DEQX.!
An error occurred whilst upgrading the
firmware
Try repeating the upgrade process. If the error
recurs, turn off the PDC (using the switch at the
back), and, whilst holding down all three profile
buttons, turn the PDC on again. This puts the
PDC into safe mode. Try repeating the upgrade
process. If the error still recurs, contact DEQX.
Note - safe mode will not do filtering or measuring,
so if the upgrade worked in safe mode, turn the
PDC off then on again. The PDC will now operate
normally.
An error occurred whilst writing to the
PDC
This can occur due to communication problems
between the PC and the PDC. Turn the PDC off
then on again (using the power switch at the back
of the PDC) and try again. If this does not restore
communications, turn the PDC off using the back
switch, then, whilst holding down the P3 button on
the front panel, turn the PDC back on again.