Installation guide

138
An exception occurred during
processing.
Unknown. Contact DEQX.
An invalid link type was found. Please
ensure that it is set to either USB or
RS232. Defaulting to USB...
If using RS232, set the COM port to the correct
port. If using USB, set the link to USB. Refer to
Setting up PDC/PC Communications for further
details.
Directory does not exist
You attempted to save a file to a directory that
does not exist. Either create the directory (using
another application such as My Computer) or
save the file to another directory.
No link with the PDC has been
detected. Do you wish to continue?
Make sure that the PDC and PC are
communicating, before commencing a
measurement.
Not all items could be removed
because they are linked by other
objects. Do you want to remove the
remainder objects and their links?
This error message occurs for example when
deleting a correction or measurement which is
referred to in a calibration template or PDC
configuration. Click Yes to remove the other
objects, or No to cancel the deletion.
The changes cannot be applied
because this would result in an
unrealizable crossover. Try reducing
the slope or increasing the frequency.
The PDC has an upper limit for delay. This upper
limit may be exceeded if the slope of a crossover
is too high or if the frequency of the crossover is
too low.
The changes cannot be applied
because this would result in
unrealizable limit filters. Try reducing
the slope or increasing the frequency.
The PDC has an upper limit for delay. This upper
limit may be exceeded if the slope of a limit filter is
too high or if the frequency of the limit filter is too
low.
The connected PDC is not using up to
date firmware. Do you wish to upgrade
now?
The DEQX-Cal software on your PC has detected
that the firmware on the PDC is not up to date.
Click Yes to upload the latest firmware from your
PC to the PDC.
The connection to the PDC was not
detected.
The link between the PDC and PC was lost during
the measurement. Make sure the cable has not
come loose and the PDC is still switched on.
The correction filter could not be
designed to the specifications entered.
No phase correction has been
designed. You can remedy this by
increasing the maximum delay, or the
tolerance in the group delay and
magnitude.
You have specified parameters for the correction
filter that collectively cannot be achieved. Increase
the Maximum Delay, the Magnitude Tolerance or
the Group Delay Tolerance.
The name is being used by another
Manufacturer. Press retry to select
another.
This message appears if you attempt to enter the
name of an existing Manufacturer as a new entry.
Choose another name.
The name is being used by another
Model. Press retry to select another.
This message appears if you attempt to enter the
name of an existing Speaker Model as a new
entry. Choose another name.