Operation Manual

Settings programming
Note: HD2000 Urgence standard factory settings come
with:
- Programming access code = 0000
- Dialling = Tone
- Hook-Flash duration = 270 ms
- Pulse mark-break ratio = 66/33
- Access to memory programming =
unlocked
- Call barring = unlocked
To change settings, proceed as follows:
1) Make sure the telephone is connected to a powered
C.O. or PABX line.
2) Depress « PGR » key located on the small keypad
(Located at the back of the unit).
3) While keeping « PGR » key depressed, pick-up the
handset.
4) Release « PGR » key.
5) 2 sharp « beep » tones will confirm entering the
settings programming mode.
6) Enter the 4 digits programming access code with the
keypad (factory pre set code is: 0000)
This code can be modified (see « LIST OF
SETTINGS » section, pages 24-25).
7) If the right code is entered, 2 short « beep » tones
will be heard and the access to settings, changes will be
authorized.
If a wrong code is entered, a low « beep » tone will be
heard and the unit will return to talk mode.
8) Enter the 2 digits selected setting access code (see
« LIST OF SETTINGS » section pages 24-25)
9) 2 sharp « beep » tones confirming the selection will
be heard.
10) Enter your custom setting choice or the code or
number to store.
11) Terminate your setting by depressing « PGR » key.
22