TEMP Quick Start & Instructions For Use 820.
1. Get TestFlight 2. Join the Beta Open this link from your phone or tablet: https://testflight.apple.com/join/htMatc38 Click "View in App Store" Download TestFlight & ensure the download has completed Return to the page from Step 1, or click this link again: https://testflight.apple.com/join/htMatc38 Click "Start Testing" to complete Step 2. This should open the TestFlight app. You will be guided through the installation process. 3. Stick To Activate 4.
Important: Read instructions carefully before use. High, prolonged fever requires medical attention. If symptoms persist, contact your healthcare provider. Important: Read the instructions for use before using NIRA Temp Introduction to NIRA Temp Welcome to NIRA Temp, a wearable smart thermometer. NIRA Temp is a Bluetooth® wearable smart thermometer with disposable patches. The device senses, records and transmits body temperature via Bluetooth®.
Alert Levels The device uses color coding to aid the user: °F °F °F °F °F Warning – Prompt response by user is required. (Temperature exceeds user defined warning limit, the default value range is 97.8°F - 98.78°F (36.5°C - 37.1°C)). °F °F °F °F °F °F °F °F Normal - (temperature is less than user defined warning limit, the default value is 95.36°F - 97.8°F (35.2°C-36.56°C)). °F °F Alarm – Immediate response by user is required.
For Best Results Wear NIRA Temp all day for the full benefits of 24/7 temperature tracking. Peel the adhesive patch and center the device onto the patch with the sensor (metal piece) side up. Apply the patch with the device onto clean, dry skin in the center of the armpit. For best results, use NIRA Temp on a shaven armpit. Ensure that the device is fully covered by the patch. The sensor should touch the skin. The device should be fully enclosed in the armpit when your arm is relaxed along your side.
Warnings and Precautions When using this product always follow these basic safety precautions to ensure that the patch accurately reads temperature and to avoid skin irritation. Failure to follow these precautions could result in inaccurate temperature readings, or could result in skin irritation and mild discomfort. DO NOT use the device for any other purpose besides measuring human body temperature. DO NOT place the device on wounds, sores or abrasions. DO NOT drop or throw the device.
Instruction for NIRA Temp App Start the App Pair the Device Start the App Pair the Device with QR code Once the app is downloaded and installed. Tap to open the app. QR code found on the sensor side of the device. 1 2 Temp Scan the Device Pair Successfully Once located, tap scan Place camera over the QR code. 3 Message will appear that the device have been paired successfully.
Pair the Device Pair the Device with Bluetooth Stick to Activate Apply device to skin to activate. Tap "No QR Code? Pair with Bluetooth" located on the Pair Screen. 1 Scan the Device 2 Pair Successfully Message will appear that the device have been paired successfully. Wait 3 to 5 min for the device to reach nominal temperature in order for the device to be scanned by the app.
Pair the Device Register the Device Add Device Afterwards Add additional devices afterwards. Go to People and tap the "Add/plus sign" in the corner of the app. Fill in the information about device user after device is paired.
Graph View Data View Graph The graph detail screen shows user current temperature and previous temperature in a graph and data form. °C °C °C °C °C To view data tap "Data". To view graph tap "Graph". Data can be viewed in 6H(6 hours) 12H(12 hours) 1D(1 day) 7D(7 days) or 14D(14 days). 1 2 Add Note Notes are available at any data point. °C To add note go to > add note > select note detail > type in your notes > tap add note.
Graph Share Data Share Data with a Person To share you data with a person tap > 3 dot on top right °F °F To share you data with a person tap > 3 dot on top right > select person > input email address > check data you want to share (temperature, share warnings, share alarms, or share location) > tap share profile °F °F °F 1 Share Data with an Organization To share you data with an organization tap > 3 dot on top right > select organization > input organization ID > organization password > student or
People People Tab Add a Device Afterwards To add a device go to > + > pair using qr code > tap scan > device is paired The people screen allows you to see your device as well as devices that are shared with you. °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F °F To see device data tap on the device you want and it will take you to the data tab of that device.
Settings Manage People Alert and Warning Allow you to see your profile as well as share and receive people temperature data. To see your profile tap settings > manage people > pick your profile > profile > update profile > save changes Alerts and warnings are have a default setting but can be changed by the user. To change user setting go to > settings > manage people > tap on the user and device > select warning threshold > select alarm threshold > tap save.
Settings Notifications Data Management Data management allows user to select what type of data can be pushed to the cloud from the phone. Notification allows you to receive alerts and warnings via app, SMS or email. Notification for warnings, alarms, device is offline, profile is shared with me, shared profile is deleted and offers and promotions can be selected by user.
Settings Low Temperature Alert About Display NIRA Temp Version Allow user to turn low temp alerts on or off. NIRA Temp FCC ID Term of Use How it works Privacy Policy 1 2 Device Management To log out > select log out > tap log out > user will be log out.
Settings Accounts Allows user to create account and order new device and supplies . To create new account > select account > fill in your profile > tap saves To edit account > select account > tap edit > tap save To order new device or supplies > select order new device or supplies > follow the order instructions > email confirmation will be sent via email.
Specifications Model Number Device Dimensions Device Weight Device Operating Life Mode of Operation Environmental Conditions •Storage •Shipping •Use Temperature Measurement Location Temperature Range Temperature Indications Accuracy or Essential Performance Battery Accuracy Transmission Distance Compatible Smart Devices Standards Regulatory Requirements Water Ingress Protection IMPORTANT: Type BF Applied Part Model 2 30 mm x 22 mm x 6 mm 4 grams 12 Months Direct Mode Storage Conditions: Temperature -4°
Warranty NIRA is committed to quality. NIRA Temp device is rigorously designed for quality and performance. This limited warranty covers defects in materials and workmanship of your NIRA Temp device if you purchased it from an authorized partner or directly from the manufacturer (NIRA). Your limited warranty is valid for you alone, the original purchaser and cannot be transferred. The limited warranty begins on the date of purchase and is in effect for 30 days.
EMC Information The NIRA Temp needs special precautions regarding EMC and needs to be used according to EMC information. The device contains hardware capable of Bluetooth Low Energy (BLE) communication. This hardware can receive and transmit RF energy in 2400—2483.5 MHz frequency range with GFSK modulation. It is compliant with CFR Title 47, FCC part 15.247, and equivalent isotropically radiated power is less than 10 dBm (10mW). Caution: Mobile RF communications equipment can affect the NIRA Temp device.
Electromagnetic Emissions Declaration The NIRA Temp is intended for use in the electromagnetic environment specified below. The customer or the user of the NIRA Temp should assure that it is used in such an environment. RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B Harmonic emissions IEC 61000-3-2 Complies Voltage fluctuations/ flicker emissions IEC 61000-3-3 Complies The NIRA Temp uses RF energy only for its internal function.
Test specifications for NIRA Temp immunity to RF wireless communications equipment Test frequency (MHz) 385 450 Service a) Modulation b) Maximum power (W) Distance (m) IMMUNITY TEST LEVEL (V/m) 380 –390 TETRA 400 Pulse modulation b) 18 Hz 1.8 0.3 27 430 – 470 GMRS 460, FRS 460 FM c) ± 5 kHz deviation 1 kHz sine 2 0.3 28 704 – 787 LTE Band 13, 17 Pulse modulation b) 217 Hz 0.2 0.3 9 800 – 960 GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 Pulse modulation b) 18 Hz 2 0.
Symbols The following symbols are used within this document or on the NIRA Temp device, mobile application and its packaging: IP67 NON STERILE Read Instruction For Use Radiofrequency Radiation Dust tight. Protection against the effects of immersion in water up to 1 m for 30 minutes.
TEMP Customer Care NIRAtemp.com info@NIRAskin.