Operating instructions
MAINTENANCE
BEARING LUBRICATION (CONT’D)
The recommended lubricant for the shaft bearings is NLGI grade 2 mineral oil lithium or lithium
complex base grease. Grease should be injected into grease fitting until purged through the fitting
regardless of the quantity added. Bearings should be re-lubricated in accordance with the
following schedule:
Daily Operating
Hours
Interval
(Weeks)
8 10
16 5
24 3
TROUBLESHOOTING
Fault diagnosis is As long as the mud level in the tank remains at or above the pump bolting flange,
the degasser will circulate fluid up to the spray tank. Malfunctions are generally caused by incoming
power disruptions or tripping of overloads or blown fuse(s) in the electrical power source. Always
check these items and for correct incoming power first before proceeding with further checking and
tests.
If degasser is equipped with a Derrick-supplied electrical control panel, an electrical schematic
diagram is included in Section 8 for assistance in tracing electrical malfunctions. If equipment is
operated by a customer-supplied starter box or other power source, consult the corresponding
electrical diagram for assistance in fault analysis. Before performing electrical continuity checks,
always shut down, lock out, and tag out electric power to degasser.
WARNING! TO AVOID SERIOUS PERSONAL INJURY BE SURE EQUIPMENT IS
LOCKED OUT, TAGGED OUT, AND DE-ENERGIZED PRIOR TO PERFORMING
MAINTENANCE.
ACD-1500 DEGASSER TROUBLESHOOTING
Trouble Possible Cause Remedy
Degasser fails to start No power or incorrect
supply voltage
Check that power is available at equipment,
and verify that correct power is supplied to
degasser.
Incorrect electrical
connections
Check and correct any wiring defects.
Improper installation Refer to Section 3. Degasser not
operating properly.
Incorrect startup
procedure
Shut down unit and restart per Section 4.
5-2 15 Apr 11
ACD-1500Degasser