WIRING CHART
PART NO. COLOR LENGTH FROM TO
1110 GREEN 4 1/2” Flame Control (Ground) Ground
1721 Red (Hi-Temp) 13” High Limit Switch Valve (Yellow or Black)
1721 Red (Hi-temp) 13 High Limit Switch Harness (Red)
1722 Red (Hi-Temp) 23” High Limit Switch Flame Control (Valve)
1617 Orange 19” Flame Control (Ignition) Electrode
1807 Black 12” Gas Valve High Limit Switch
1807 Black 12” Gas Valve Flame Control
1959 Green 7” Flame Control (Harness) Ground
1959 Red 7” Flame Control (Harness) High Limit Switch
1959 White 6 Flame Control (Harness) Terminal Block
1959 Black 6” Flame Control (Harness) Terminal Block
INSTRUCTIONS FOR ORDERING PARTS
All parts orders must show heater Model No., Item No., Part
No., and Description. We recommend that only parts sup-
plied by the manufacturer be used on this unit. A locally
purchased part may appear to be identical, although in real-
ity it might endanger the heater or the persons operating the
heater.
The heater should be serviced only by a trained,
experienced service person.
Read the section on “Servicing” before ordering
parts.
For parts order, call (909) 981-5343.
CONNECTION DIAGRAM
SCHEMATIC DIAGRAM
ELECTRODE
HI-LIMIT
SWITCH
GAS
VALVE
CHASSIS
GROUND
MOTOR
THERMOSTAT
LINE CORD
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
ELECTRODE
ELECTRODE
MOTOR
MOTOR
GAS
VALVE
GAS
VALVE
FLAME
CONTROL
(CP MARK 10 DN)
LINE
NEUTRAL
VALVE
GREEN
TB
THERMOSTAT
LINE CORD
CHASSIS
GROUND
HI-LIMIT
SWITCH
VALVE (V2)
VALVE (V1)
LINE (L1)
NEUT (L2)
GRD
FLAME
CONTROL
(RAM 1M501)
(CP MARK 10 DN)
THERMOSTAT
HI-LIMIT
SWITCH
FLAME
CONTROL
GROUND
(GRN) (B/G)
NEUTRAL
(WHT)
(L2)
IGN
(ORG)
LINE
(BLK)
(L1)
VALVE
(RED)
(MV) (V1)
ALT.
VALVE
CONN.
(MVG) (V2)
B BLACK R RED
G GREEN W WHITE
Y YELLOW
O ORANGE
TERMINAL BOARD
Y TERMINAL
MALE CONN.
FEMALE CONN.
COLOR CODE
LEGEND
If any original wiring as supplied with the heater must be replaced, it must be replaced with
type AWG 105
o
C wire or its equivalent except as indicatd (*type SF 2-200, **SGI 250
o
C)
7403C
WIRING DIAGRAM
3500FAC-V