DESA INTERNATIONAL UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
CONTENTS SECTION PAGE Safety Information ................................................................................... 2 Product Identification .............................................................................. 4 Local Codes ............................................................................................. 5 Unpacking ................................................................................................ 5 Product Features ............................................
SAFETY INFORMATION Continued WARNING ICON G 001 WARNINGS Continued WARNING: Any change to this fireplace or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3.
PRODUCT IDENTIFICATION Crossover Log (#3) Front Log (#2) Rear Log (#1) Front Burner Rear Burner Left Front Branch (#4) Gas Regulator Base Right Front Branch (#5) Figure 1 - Log Base Assembly Top Louver Assembly Top Outer Casing Firebox Hood Firebox Support Rear Access Door Screen Assembly Side Access Door Bottom Louver Assembly 4 Figure 2 - Fireplace 102667
LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 UNPACKING 1. Place the carton containing the fireplace unit on its back. Hold fireplace and pull the carton and pallet away.
AIR FOR COMBUSTION AND VENTILATION WARNING ICON G 001 WARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes.
AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = ___________________ cu. ft.
AIR FOR COMBUSTION AND VENTILATION Continued WARNING ICON G 001 WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3. VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
INSTALLING NOTICE A qualified service person must install fireplace. Follow all local codes. WARNING ICON G 001 WARNING Never install the fireplace • in a bedroom or bathroom • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas WARNING This fireplace has a three-prong, grounded electrical plug.
INSTALLING Continued ASSEMBLING AND ATTACHING BRASS TRIM Note: The instructions below show assembling and attaching brass trim to fireplace. 1. Remove packaging from three pieces of brass trim. 2. Locate four brass screws, two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 5. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 5). 5.
INSTALLING INSTALLATION CLEARANCES Continued WARNING ICON G 001 WARNING Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall. Carefully follow the instructions below. This will ensure safe installation. Minimum Wall and Ceiling Clearances (see Figure 7) A. Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation. B.
INSTALLING Continued 3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 16. 4. Place hearth base accessory against wall at installation location. Cut an access hole in hearth top to run flexible gas line to fireplace (see Figure 8).
INSTALLING Continued 9. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17. 10. Route blower electrical cord through side or rear access door of fireplace. Plug electrical cord into electrical outlet. 11. Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any laminate trim on hearth base. Remove protective material from top of hearth base and from front of fireplace (if any).
INSTALLING If installing in a corner, use dimensions shown in Figure 13 for the rough opening. The height is 33" which is the same as the wall opening, on page 13. n Continued 39 3/8" 27 7/8" 35 1/2" 55 5/8" Figure 13 - Rough Opening for Installing in Corner 2. Install a properly grounded, three-prong 120 volt electrical outlet at fireplace location. Locate outlet inside the framed enclosure. 3. Install gas piping to fireplace location.
INSTALLING Continued Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
INSTALLING Continued The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 16. Pointing the vent down protects it from freezing rain or sleet.
INSTALLING A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap* Continued Approved Flexible Gas Line 3" Minimum From External Regulator (11" W.C. to 14" W.C. Pressure) Tee Joint Sediment Trap Pipe Nipple Cap Figure 17 - Gas Connection * Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 32.
INSTALLING 4. Route flexible gas line from manual shutoff valve into fireplace through side or rear access panel. Route flexible gas supply line through fireplace access door. Continued NOTICE Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace. The flexible gas supply line connection to the manual shutoff valve should be accessible. 5.
INSTALLING Continued Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 20). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve (see Figure 21). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. Pressure Testing Fireplace Gas Connections 1. Open manual shutoff valve (see Figure 20). 2.
INSTALLING INSTALLING LOGS Continued WARNING ICON G 001 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1.
INSTALLING WARNING ICON Continued G 001 WARNING You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running fireplace. 5. Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 26).
OPERATING FIREPLACE ThermostatControlled Models Continued LIGHTING INSTRUCTIONS WARNING ICON G 001 WARNING You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace. NOTICE During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours. 1.
OPERATING FIREPLACE ThermostatControlled Models 8. Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO. CAUTION Do not try to adjust heating levels by using the manual shutoff valve. Continued TO TURN OFF GAS TO APPLIANCE Shutting Off Fireplace Turn control knob clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise to the PILOT position.
OPERATING FIREPLACE Manually-Controlled Models Continued LIGHTING INSTRUCTIONS WARNING ICON WARNING G 001 You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace. NOTICE During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours. 1.
OPERATING FIREPLACE Manually-Controlled Models VARIABLE CONTROL OPERATION The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort. Continued WARNING ICON G 001 WARNING Do not operate heater between locked positions.
INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 31 shows a correct pilot flame pattern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.
CLEANING AND MAINTENANCE WARNING ICON G 001 WARNING Turn off fireplace and let cool before cleaning. WARNING ICON CAUTION G 001 You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE When ignitor button is pressed, there is spark at ODS/pilot but no ignition 1. Gas supply turned off or manual shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed 5. ODS/pilot is clogged 6. Gas regulator setting is not correct ODS/pilot lights but flame goes out when control knob is released 1. Control knob not fully pressed in 2.
TROUBLESHOOTING Continued OBSERVED POSSIBLE PROBLEM CAUSE One or both burners do 1. Burner orifice(s) not light after ODS/ clogged pilot is lit 2. Burner orifice(s) diameter is too small 3. Inlet gas pressure is too low 4. Mislocated crossover tube Delayed ignition of one or both burners 1. Manifold pressure is too low 2. Burner orifice(s) clogged 3. Mislocated crossover tube Burner backfiring during combustion 1. Burner orifice is clogged or damaged 2. Damaged burner 3.
TROUBLESHOOTING Continued WARNING ICON G 001 WARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating fireplace where impurities in air exist may create odors.
TECHNICAL SERVICE SERVICE HINTS You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the address listed on the back page of this manual.
ACCESSORIES Continued ¢¢¢¢¢¢ ,,,,,, QQQQQQ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ CORNER MANTEL GM200F - Walnut Finished GM201U - Unfinished Shown with optional laminate mantel trim accessory.
ILLUSTRATED PARTS BREAKDOWN 3 Log Base Assembly Variable ManuallyControlled Models 1 2 4 5 7 7-1 7-2 27 13 19 8 18 9 10 8 6 8 23 12 11 8 16 26 22 6 14 6 21 6 24 6 29 15 30 VGF28PV CFGF28PV 25 20 32 31 19 28 17 34 102667
PARTS LIST Log Base Assembly Variable ManuallyControlled Models This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. VGF28PV CFGF28PV KEY NO.
ILLUSTRATED PARTS BREAKDOWN 3 Log Base Assembly ThermostatControlled Models 1 4 2 5 7 7-1 7-2 27 19 8 13 9 10 6 8 12 11 8 16 26 6 14 6 29 20 6 18 6 28 15 21 19 24 7-2 13 VGF28PTA CFGF28PTA 25 17 22 23 36 102667
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. PARTS LIST Log Base Assembly ThermostatControlled Models VGF28PTA CFGF28PTA KEY NO.
ILLUSTRATED PARTS BREAKDOWN Fireplace 7 10 17 1 6 16 16 11 9 2 4 12 8 3 25 25 14 13 16 16 16 25 15 5 30 6 21 16 26 19 22 7 16 29 23 18 28 16 20 27 24 38 102667
PARTS LIST Fireplace This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. VGF28PV/CFGF28PV VGF28PTA/CFGF28PTA KEY NO.
SPECIFICATIONS WIRING DIAGRAMS Btu (Low/High) 20,000/28,000 Type Gas LP Gas Only Ignition Piezo Manifold Pressure 7.9" W.C. Inlet Gas Pressure (in. of water) Maximum Minimum 14" 11" Shipping Weight 92 lbs. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Fan Switch (Off/On) Off 1 2 On Black 110/115 V.A.C.
NOTES 41 102667
NOTES
NOTES
WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.