Owner's Manual

103507
GAS RESIDENTIAL HEATERS
®
16
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
Yellow
Tipping
Top of
Flame
About One
Inch Above
Logs
If burner flame pattern is incorrect, as shown in Figure 29
turn heater off (see To Turn Off Gas to Appliance, page 15).
see Troubleshooting, pages 17 through 19.
INSPECTING
BURNER
Continued
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized
air, or small, soft bristled brush to
clean.
CABINET
Air Passageways
Use a vacuum cleaner or pressurized
air to clean.
Exterior
Use a soft cloth dampened with a
mild soap and water mixture. Wipe
the cabinet to remove dust.
Figure 29 - Incorrect Burner Flame Pattern
Figure 28 - Correct Burner Flame Pattern
SPECIFICATIONS
Btu (Variable) 14,000/28,000
Type Gas Propane/LP Only
Ignition Piezo
Pressure Regulator Setting 8" W.C.
Inlet Gas Pressure (in. of water) *
Maximum 14"
Minimum 11"
Dimensions, Inches (H x W x D)
Heater 23.75 x 25.9 x 8.5
Carton 25.8 x 28.7 x 10.1
Weight (pounds)
Heater 29
Shipping 35
* For purposes of input adjustment