Owner's Manual

103507
GAS RESIDENTIAL HEATERS
®
8
WARNING: Never install the
heater
in a bedroom or a bathroom
in a recreational vehicle
where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater
as a fireplace insert
in high traffic areas
in windy or drafty areas
WARNING: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities in the air (such
as tobacco smoke) exist, may
discolor walls.
INSTALLATION
NOTICE: A qualified service per-
son must install heater. Follow
all local codes.
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have
the items listed below.
external regulator (supplied by
installer, see page 20)
piping (check local codes)
sealant (resistant to propane/LP gas)
manual shutoff valve *
ground joint union
test gauge connection * (see Figure
21, page 12)
sediment trap
tee joint
pipe wrench
* An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 20.
LOCATING HEATER
WARNING: Maintain the mini-
mum clearances shown in Figure
10. If you can, provide greater
clearances from floor, ceiling, and
joining wall.
You can locate heater on floor. The optional
hearth base is needed. You can also install
optional decorative mantels on the heater
(some mantels require the hearth base). I
M-
PORTANT:
Only use optional mantels and
hearth base specified in this manual. Pur-
chase the optional mantel and hearth base
from your dealer. See Accessories, pages 20
and 21.
The heater may also be mounted on a wall.
You cannot use optional mantel if mounting
heater on a wall.
Figure 10 - Mounting Clearances As Viewed From Front of Heater
36"
5"
FLOOR
CEILING
Minimum
Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material
6"
Minimum
From
Sides Of
Heater
Left
Side
Right
Side
IMPORTANT:
Vent-free heaters add mois-
ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Fresh Air for Com-
bustion and Ventilation, pages 5 through 7.
CAUTION: If you install the
heater in a home garage
heater pilot and burner must be
at least 18 inches above floor.
locate heater where moving ve-
hicle will not hit it.
For convenience and efficiency, install heater
where there is easy access for
operation, inspection, and service.
in coldest part of room.
An optional fan kit is available from your
dealer. See Accessories, page 20. If plan-
ning to use fan, locate heater near an electri-
cal outlet.