Owner's Manual

20
103508
VENT-FREE NATURAL GAS RADIANT
®
FLAME HEATER
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air
to clean.
Exterior
Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.
BTU (Variable) 14,000/28,000
Type Gas Natural Only
Ignition Piezo
Pressure Regulator Setting 3" W.C.
Inlet Gas Pressure (in. of water) *
Maximum 10.5"
Minimum 5"
Dimensions, Inches (H x W x D)
Heater 23.75 x 25.9 x 8.5
Carton 26 x 27.75 x 10.25
Weight (pounds)
Heater 29
Shipping 35
* For purposes of input adjustment
SPECIFICATIONS
When Gas Pressure Is Too Low
pilot will not stay lit
burner will have delayed ignition
heater will not produce specified heat
When Gas Quality Is Bad
pilot will not stay lit
burner will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.
SERVICE HINTS
CAUTION : You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.
WARNING: Turn off heater
and let cool before cleaning.