INSTALLATION ITEMS
Before installing replace, make sure you have
the items listed below.
• external regulator (supplied by installer, for
propane/LP units only)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection*
• ground joint union
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certied equipment shutoff valve from your
dealer. See Accessories, page 44.
Note: If desired, purchase a four-sided brass trim
kit for built-in installations. See Accessories,
page 44.
WARNING: Maintain the
minimum clearances shown
If your replace is to be used with an optional
mantel, the installation instructions included with
your mantel shows an CSA approved method of
attaching the replace/mantel system to a wall.
IMPORTANT: Only use optional cabinet or
corner mantels specied in this manual. Purchase
the optional mantel from your dealer (see Acces-
sories, page 44).
If your replace is to be recessed into the wall,
see Built-In Fireplace Installation to secure your
replace into the wall.
CAUTION: If you install the
For convenience and efciency, install replace
• where there is easy access for operation, inspec-
tion, and service
• in coldest part of room
An optional blower kit is available from your
dealer. See Accessories, page 44. If planning to use
blower, follow instructions provided with blower
for power source.
Minimum Clearances For Side
Combustible Material, Side Wall, and
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 7.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This combus-
tible material must be 4" from the side of the
replace opening (see Figure 7).
B.
Clearances from the top of the replace opening
to the ceiling should not be less than 36 inches.
C.
For mantel clearances, see Figure 11, page 12.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top Left and Bottom
36" 6" 0"
Figure 7 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
*
Example
INSTALLATION
Continued
INSTALLATION
Built-in installation of this fireplace involves
installing replace into a framed-in enclosure.
This makes the front of replace ush with wall.
An optional brass trim kit accessory is available
(see Accessories, page 44). Brass trim will extend
past sides of replace approximately 1/2" . This
will cover the rough edges of the wall opening. If
installing a built-in mantel above the replace, you
must follow the clearances shown in Figure 12,
page 12. Follow the instructions below to install
the replace in this manner.