INSTALLATION ITEMS
Before installing replace, make sure you have
the items listed below.
external regulator (supplied by installer, for
propane/LP units only)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection*
ground joint union
sediment trap
tee joint
pipe wrench
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certied equipment shutoff valve from your
dealer. See Accessories, page 44.
Note: If desired, purchase a four-sided brass trim
kit for built-in installations. See Accessories,
page 44.

WARNING: Maintain the
minimum clearances shown

   

If your replace is to be used with an optional
mantel, the installation instructions included with
your mantel shows an CSA approved method of
attaching the replace/mantel system to a wall.
IMPORTANT: Only use optional cabinet or
corner mantels specied in this manual. Purchase
the optional mantel from your dealer (see Acces-
sories, page 44).
If your replace is to be recessed into the wall,
see Built-In Fireplace Installation to secure your
replace into the wall.
CAUTION: If you install the

 
     

 

For convenience and efciency, install replace
where there is easy access for operation, inspec-
tion, and service
in coldest part of room
An optional blower kit is available from your
dealer. See Accessories, page 44. If planning to use
blower, follow instructions provided with blower
for power source.
Minimum Clearances For Side
Combustible Material, Side Wall, and

A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 7.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This combus-
tible material must be 4" from the side of the
replace opening (see Figure 7).
B.
Clearances from the top of the replace opening
to the ceiling should not be less than 36 inches.
C.
For mantel clearances, see Figure 11, page 12.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top Left and Bottom
 
36" 6" 0"
Figure 7 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
*
Example
INSTALLATION
Continued

INSTALLATION
Built-in installation of this fireplace involves
installing replace into a framed-in enclosure.
This makes the front of replace ush with wall.
An optional brass trim kit accessory is available
(see Accessories, page 44). Brass trim will extend
past sides of replace approximately 1/2" . This
will cover the rough edges of the wall opening. If
installing a built-in mantel above the replace, you
must follow the clearances shown in Figure 12,
page 12. Follow the instructions below to install
the replace in this manner.