6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 30. Also, contact a
qualiedservicepersonorgassupplierfor
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through7.Thisreplacehasasafetyinter-
locksystem.Waitone(1)minuteforsystem
to reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The burner should
light. Set control knob to any heat level
between HI and LO.
CAUTION: Do not try to ad-


OPERATING FIREPLACE
Continued
Figure 43 -Propane/LP Gas Pilot
Thermocouple
Ignitor
Electrode
Pilot Burner
Thermocouple
Ignitor
Electrode
Pilot Burner
TO TURN OFF GAS


1. Turn control knob clockwise to the
OFF position.
2.
Turnoffallelectricpowertotheappliance(if
applicable)ifserviceistobeperformed.

Turn control knob clockwise to the
PILOT position.
THERMOSTAT CONTROL

Thethermostatusedonthisreplacesensesthe
room temperature. At times the room may exceed
the set temperature. If so, the burner will shut off.
The burner will cycle back on when room tem-
perature drops below the set temperature.
The control knob can be set to any heat level
between HI and LO.
Note: The thermostat sensing bulb measures
the air near the replace cabinet. This may
notalwaysagreewithroomtemperature(de-
pending on housing construction, installation
location, room size, open air temperatures,
etc.).Frequentuseofyourreplacewillletyou
determine your own comfort levels.
MANUAL LIGHTING

1. Follow steps1 through 5 under Lighting
Instructions, page 22.
2. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8 under
Lighting Instructions, column 1.

BLOWER
This blower has three settings: ON, OFF, and
AUTO. In the ON position, the blower will oper-
ate constantly. In the OFF position, the blower
will not operate. In the AUTO position, the
blower will start when the thermostat senses a
sufcientincreaseinreboxtemperature.
Note:Yourreplace and thermostatblower
will not turn on and off at the same time. The
replacemayrunforseveralminutesbeforethe
blower turns on. After the heater modulates to
the pilot position, the blower will continue to
run.Theblowerwillshutoffaftertherebox
temperature decreases.
Figure 42 - Natural Gas Pilot