TROUBLESHOOTING
Continued

 
 
Do not touch any electrical switch; do not use any phone in your

 

 
IMPORTANT: Operating replace where impurities in air exist may create odors. Cleaning supplies,
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
These fumes may mix with combustion air and create odors. These odors will disappear over time.

1. Fireplace burning vapors from
paint, hair spray, glues, clean-
ers, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. -

1.
Not enough fresh air is avail-
able
2. Low line pressure
3. O D S / p i l o t i s pa r t i a l l y
clogged
1. Gas leak. -

2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. -

REMEDY
1. Open window to ventilate
room. Stop using odor caus-
ing products while replace
is running
2. Rell supply tank (propane/LP
only)
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 17)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3.
Clean ODS/pilot (see Cleaning
and Maintenance, page 28)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 17)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 17)

Fireplace produces unwanted
odors
Fireplace shuts off in use (ODS
operates)
Gas odor even when control
knob is in OFF position
Gas odor during combustion