Owner's Manual
www.desatech.com
55173-G 15
CLEANING AND
MAINTENANCE
WARNING: Installation and
repairshouldbedonebyaquali-
edserviceperson.Theappli-
anceshouldbeinspectedbefore
each use and at least annually
by a qualied service person.
Morefrequentcleaningmaybe
required due to excessive lint
fromcarpeting,beddingmate-
rial,pethair,etc.Itisimperative
thatthecontrolcompartments,
burnersandcirculatingairsys-
tembekeptclean.
WARNING:Thelogscanbe
hot. Handle only when cool.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electric power to the appliance
if service is to be performed.
2. Remove control access panel.
3. Close the gas valve.
OPERATING FIREPLACE
Continued
Figure 26 - Pilot
WARNING: Turn off gas and
electricalpowerbeforeservicing
appliance. Any safety screen
orguardremovedforservicing
mustbereplacedpriortooperat-
ing the appliance.
WARNING: Failure to keep
the primary air opening(s) of
theburner(s)cleanmayresultin
sootingandpropertydamage.
Keep control compartment, logs, burner and area
surrounding logs clean by vacuuming or brushing
at least twice a year. Take care not to alter the set-
tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning
glass doors and trims. Any household glass cleaner
should sufce. Do not clean doors when hot. Allow
appliance to cool before cleaning.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA’s
Technical Service Department at 1-866-672-6040.
When calling please have your model and serial
numbers of your heater ready.
You can also visit DESA’s Technical Services web
site at www.desatech.com.
SPECIFICATIONS
GL36ST, GL36STE
• Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
• Manifold Pressure: 3.5 W.C. (.87 kPa)
• Supply Pressure (in. of water): Minimum* - 4.5"
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
• Orice Size at Altitudes: 2,000 ft. - #30, 2,000 ft.
to 4,000 ft. - #31
GL36STP, GL36STEP
• Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
• Manifold Pressure: 11.0 W.C. (2.74 kPa)
• Supply Pressure (in. of water): Minimum* -
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
• Orice Size at Altitudes: 2,000 ft. - #49, 2,000 ft.
to 4,000 ft. - #51
* For the purpose of input adjustment