Continued
FRAMING
Construct framing using dimensions shown if
Figures 6, 7 and 8. (Use the gure applicable to
your application.) Figure 6 shows the framing
dimensions prior to having the appliance in place.
Once the unit has been tted, bring studs in against
nailing anges located on the side of the appliance
making sure a 1" clearance is maintained as shown
in Figure 7.
If the replace is to be installed directly on carpet-
ing, tile (other than ceramic) or any combustible
material other than wood ooring the replace
must be installed upon a metal or wood panel
extending the full width and depth of the replace
(see Figure 8). The platform must be solid, at and
fully supported.
Figure 6 - Framing Dimensions Prior to
Placing Appliance
Figure 7 - Securing Appliance with
Nailing Flanges
Figure 8 - Appliance Must Be Installed
on a Wood or Metal Panel if Being
Installed on Any Combustible Material
Other Than Wood
52
3
/
4
"
(1340 mm)
Min.
46"
(11688 mm)
22
3
/
4
"
(578 mm)
VENT PIPE INSTALLATION
A 6", B-1 type gas vent pipe is a double-wall, vent-
ing system (not supplied) which must be installed
during rough framing of the appliance. Any B-1
type gas vent system may be used for proper vent-
ing as long as the vent system is installed per the
vent manufacturers recommendations.
DESA supplies this appliance with a tapered starter
pipe for a snug t. Slide B-1 type vent pipe over
this starter pipe until vent pipe is fully seated.
Secure this rst section of B-vent pipe by strap-
ping the connector around the vent pipe and then
tightening the strap (not supplied) with any 1/8"
nut and bolt (see Figure 9). Note: Visually inspect
for proper vent connection by looking inside top
of appliance. If connection does not appear to be
correct, contact your local service technician.
Figure 9 - Installing B-Vent Pipe
Nailing Flanges
1" Min. to Combustibles
Prepared Framing
Nails or Screws
As Required by Design as
Long as Ceiling Clearances
are Maintained
49" Minimum
(Diagonal)
B-1 Type
Vent (Not
Supplied)
Strap (Not
Supplied)
(Fasten with
#6 Screw or
Bolt)