User Guide

www.fmiproducts.com
124970-01A4
PRODUCT FEATURES
OPERATION
This rebox is designed for use with approved
ANSI Z21.11.2 decorative type unvented room
heaters. (Physical size limitations apply. Refer
to minimum rebox requirements supplied
with log heater.) It requires no outside vent-
ing or chimney making installation easy and
inexpensive. When used without the blower,
the rebox requires no electricity making it
ideal for emergency backup heat.
BLOWER ACCESSORY
The circulating models will accept either a ro-
tary type fan (model BK) or the triple radial fan
blower system (model BK3) accessories. The
blower circulates heated air from the rebox
into the room. Use of blower is optional.
REFRACTORY BRICK LINER
Your rebox may feature a concrete refrac-
tory brick liner. As with all concrete liners,
this liner may develop slight cracks when
exposed to heat. These cracks will not affect
the performance of the replace or vent-free
gas logs.
LOCATINg FIREBOX
PLANNING
Plan where you will install the rebox. This will
save time and money later when you install
the rebox. Before installation, consider the
following:
1. Where the rebox will be located. Allow for
wall and ceiling clearances (see Installa-
tion Clearances, page 9).
2. Everything needed to complete installation.
3. These models CANNOT be installed in a
bedroom unless the maximum BTU rating
of the installed vent-free log set is less
than 10,000 Btu/Hr.
4. Proper air for combustion and ventilation
(page 6).