OWNER'S OPERATION AND INSTALLATION MANUAL WINCHESTER OAK UNVENTED (VENT-FREE) GAS LOG HEATER CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA CLD3924PTB,CLD3924NTB

www.desatech.com
113101-01A 15
CHECKING GAS CONNECTIONS
WARNING: Test all gas pip-
ing and connections , internal
and external to unit, for leaks
after installing or servicing. Cor-
rect all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a commercial leak detec-
tion solution to all joints.
Bubbles forming show a leak.
Correct all leaks at once.
CAUTION: For propane/LP
units, make sure external regula-
tor has been installed between
propane/LP supply and heater.
See guidelines under
Connecting
to Gas Supply
, page 13.
INSTALLATION
Continued
PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main
gas valve (control valve) and equipment shutoff
valve from gas supply piping. Pressures in ex-
cess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.
4. Check all joints of gas supply piping system.
Apply a commercial leak detection solution
to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve
to gas supply. Check reconnected fittings for
leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 15).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.
3. Check all joints from gas meter (natural gas)
or propane/LP supply to equipment shutoff
valve (see Figure 16 or 17). Apply a commer-
cial leak detection solution to all joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 15 - Equipment Shutoff Valve
ON
POSITION
OFF
POSITION
Open
Closed
Equipment
Shutoff
Valve
Equipment Shutoff Valve
Propane/LP
Supply Tank
Control Valve
Location
Figure 17 - Checking Gas Joints
(Natural Gas Only)
Gas
Meter
Equipment Shutoff Valve
Control Valve Location
Figure 16 - Checking Gas Joints
(Propane/LP Gas Only)