Residential Woodburning Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL (V)GM36, (V)GM42 and (V)GM50 Wood Burning Masonry Fireplaces with Insulation (V)GM36H, (V)GM42H and (V)GM50H Wood Burning Herringbone Masonry Fireplaces with Insulation SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assistance or additional information. Consult a qualified installer or local distributor. Table of Contents Safety Information................................................ 2 Specifications....................................................... 3 Fireplace Installation............................................ 6 Venting Installation...................
Specifications Models VGM36(H) and GM36(H) ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 1" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 11/2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 12" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 60" X 20" 0" TO BOTTOM 12" EACH SIDE 29" 12" 7.5" 67" 22" 58" 26.625" 49" 30" 0.625" 45" 36" 8" 1" 45" AIR KIT KNOCK OUT LEFT SIDE 21.5" GAS LINE KNOCK OUTS 3.5" 10.
Specifications Continued Models VGM42(H) and GM42(H) ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 11/2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 66" X 20" 0" TO BOTTOM 12" EACH SIDE 12" 30.5" 11" 67" 21.25" 58" 49" 30" 28.5" 0.625" 51" 42" 8" 1" 51" AIR KIT KNOCK OUT LEFT SIDE 24.
Specifications Continued Models VGM50(H) and GM50(H) ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 11/2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS 0" TO BOTTOM 12" EACH SIDE HEARTH EXTENSION 74" X 20" 12" 38.5" 11" 67" 21.25" 58" 49" 30" 28.5" 0.625" 59" 50" 8" 1" 59" LEFT SIDE 32.
Fireplace Installation Framing selecting location To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where the fireplace will not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. 4.
Fireplace Installation Mantels Continued Hearth Extension A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick.
Venting Installation PART NO. Optional Outside air Kit (Model ak4/ak4f) The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). CAUTION: Combustion air inlet ducts shall not terminate in attic space. Secure to Collars with Metal Tape, Screws or Straps (Min.
Venting Installation Continued Using ELBOW offsets (30E-12DM) 1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7). OFFSET A RISE B 12" CHIMNEY LENGTH 18" 24" 36" 48" 2. Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 8, details a and b). 3. Maximum length of pipe between supports (return elbow or 12S-12DM) is 6' of angle run.
Venting Installation Continued Screws B A Figure 9 - Elbow Offset Penetrating the roof To maintain a 1" (GM36) or 2" (GM42/GM50) clearance to the pipe on a roof with a pitch, a rectangular opening must be cut. 1. Determine the center point through which the pipe will penetrate the roof. 2. Determine the center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters.
Venting Installation Continued 4. Remove the shingles around the opening measured. Cut out this section. 5. Add the next sections of the pipe until the end penetrates the roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof.
Venting Installation Continued Chase installations Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24" center to center and stacked at a vertical height difference of 18" (see Figure 16).
Optional Gas Line Installation Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BY A QUALIFIED SERVICE PERSON.
Brick Installation Installing Brick "S" Use brick “S” if an optional gas line is installed. Mount brick “S” as shown in Figure 21. It is important that the knockout hole is in its proper location. The knockout hole on brick “S” should align with the hole on the brick housing. Installation of brick should be done after the fireplace is placed in a permanent location. The brick housing panels are already installed in the firebox. Each housing is stamped with a letter (full size bricks are not stamped).
Brick Installation Continued Standard Brick Installation for Model (V)GM36 LEFT PANEL Q P AF AG FULL AF AF C C FULL AE FULL AE AE AF AG FULL AF FULL D FULL FULL D AN AF FULL AC C P FULL AG AC C FULL C AE FULL FULL Q AH AI D FULL FULL D AC AD Q D FULL FULL D AE FULL AG C AC AG FULL Q AI AE FULL RIGHT PANEL REAR PANEL AH AT AD AG HEARTH PANEL G H G FULL H FULL FULL I FULL FULL M FULL I FULL FULL AB L M L L AB HERRINGBONE Brick Installation for Mo
Brick Installation Continued Standard Brick Installation for Model (V)GM42 LEFT PANEL Q O D FULL FULL C D D FULL FULL R Full F FULL U FULL Y V FULL FULL FULL W X AA FULL FULL D FULL C OR **S U Y **See instruction on page 14 before installing brick "S" V FULL FULL K L C Full FULL FULL K L D FULL FULL HEARTH PANEL OR **S C A E D FULL FULL B O FULL A F FULL FULL B E FULL Q A E FULL E B F FULL FULL F B FULL FULL E A Z FULL E F B FULL C
Brick Installation Continued Standard Brick Installation for Model (V)GM50 REAR PANEL LEFT PANEL O D FULL C D P R FULL E B B FULL FULL AN F FULL Full B E FULL FULL FULL G H FULL FULL FULL I Full M FULL FULL OR **S H FULL FULL FULL **See instruction on page 14 before installing brick "S" G FULL FULL D C HEARTH PANEL OR **S D C FULL AT F D C FULL A FULL FULL FULL B F O FULL A F FULL FULL Q B E FULL FULL R E FULL FULL FULL E P FULL FULL
Brick Installation Continued Standard Brick Matrix - (V)GM36 Brick Matrix Box #1 Hearth-36 Box #2 Rear-36 Box #3 Left or Right-36 Box #4 Left or Right-36 TOTAL Standard brick matrix for model (V)GM36 Full A B C D E F G H I J K 8 - 2 2 2 9 - 6 6 5 5 27 0 0 6 6 0 0 2 2 2 0 0 L 3 3 M 2 2 Standard brick matrix for model (V)GM36 (Continued) Brick Matrix Q R S T U V W X Y Z AA Box #1 Hearth-36 Box #2 Rear-36 2 Box #3 Left or Right-36 1 Box #4 Left or Right-36 1 TOTAL 4 0 0 0 0 0 0 0 0 0 0 AB 2 2 N 0 AC 3 3
Brick Installation Continued Standard Brick Matrix - (V)GM42 Brick Matrix Box #1 Hearth-42 Box #2 Rear-42 Box #3 Left or Right-42 Box #4 Left or Right-42 TOTAL Standard brick matrix for model (V)GM42 Full A B C D E F G H I J K 10 - 4 9 - 6 6 9 3 3 3 3 9 3 3 3 3 37 6 6 6 6 6 6 0 0 0 0 4 L 4 4 Standard brick matrix for model (V)GM42 (Continued) Brick Matrix Q R S T U V W X Y Z AA AB AC Box #1 Hearth-42 - 2 2 2 2 2 2 Box #2 Rear-42 1 - 2 Box #3 Left or Right-42 1 1 1 Box #4 Left or Right-42 1 1 1 TOTAL 3 2
Brick Installation Continued Standard Brick Matrix - (V)GM50 Brick Matrix Box #1 Hearth-50 Box #2 Rear-50 Box #3 Left or Right-50 Box #4 Left or Right-50 TOTAL Standard brick matrix for model (V)GM50 Full A B C D E F G H I J K 12 - 2 2 2 2 4 15 - 6 6 9 3 3 3 3 9 3 3 3 3 45 6 6 6 6 6 6 2 2 2 2 4 L 4 4 Standard brick matrix for model (V)GM50 (Continued) Brick Matrix Q R S T U V W X Y Z AA Box #1 Hearth-50 Box #2 Rear-50 3 Box #3 Left or Right-50 1 1 Box #4 Left or Right-50 1 1 TOTAL 5 2 0 0 0 0 0 0 0 0 0
Brick Installation Continued Installing Z-shaped Grate Retainer Bracket Before grouting the bricks, locate the z-shaped grate retainer brackets on top of the hearth bricks as shown in Figure 22. Position the retainer brackets at 8 3/4" apart from center to center of notch. Model GM36 GM42 GM50 Distance Apart 3 1/4" Centers 4 1/4" Centers 8 3/4" Centers See Chart for Grate Retainer Brackets Location Figure 22 - Installing Grate Retainer Bracket Grouting instructions Material provided: 2 - 9 lb.
Glass Door Installation IMPORTANT: Install glass door frame before installing glass door. DOOR MODELS BDM36E/G/C, BDM42E/G/C AND BDM50E/G/C Assembly Insert L-shaped gussets starting at left top portion of door frame. Gusset holes should align with screw holes on the frame. Secure using flat head screws. Flat Head Screw door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO50E/G/C Installation 1. Remove screws from smoke shelf (see Figure 26). 2.
Glass Door Installation Operation and Maintenance Guidelines Continued Glass Doors Installing glass doors Spring clips have been installed but some adjustments may be needed. Install the doors using the following steps: 1. With bi-fold doors completely folded, insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door track. Door is installed when top door pin snaps into spring clip. 2.
Operation and maintenance Guidelines Damper Weight Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from the fire and smoke.
Replacement and Accessory Parts Bi-Fold Glass Masonry Door BDM36E - 36" Ebony BDM36G - 36" Pewter BDM36C - 36" Oiled Bronze BDM42E - 42" Ebony BDM42G - 42" Pewter BDM42C - 42" Oiled Bronze BDM50E - 50" Ebony BDM50G - 50" Pewter BDM50C - 50" Oiled Bronze Grate 109496-03 - Model GM36 109496-02 - Model GM42 109496-01 - Model GM50 Ember Protector - EP36 BDMO36E - 36" Ebony BDMO36G - 36" Pewter BDMO36C - 36" Oiled Bronze BDMO42E - 42" Ebony BDMO42G - 42" Pewter BDMO42C - 42" Oiled Bronze BDMO50E - 50" Ebony
Replacement and Accessory Parts Continued Roof Flashing V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch Round ToP TErminations RLT-12D and RLT-12HT SQUARE CHASE-TOP TERMINATION - STL-12D 26 www.desatech.
NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________