Specifications

111
RESET FEATURE
This dive computer is configured with a RESET feature that allows data to be cleared, including Ni-
trogen and Oxygen calculations, FO2 set point, Log Mode entries, and Download data.
WARNING: Reset after a dive and subsequent use for a repetitive dive con-
ducted by the same diver could result in serious injury to or death.
RESET PROCEDURE
While in SURFACE MODE (new activation period or greater than a 10 minute post dive surface
interval), press the Advance (Front) button one (1) time to access PLAN MODE.
While 30 feet (or 9 meters) is displayed in the PLAN MODE, press and hold Both buttons until
SET 2 appears, then release the buttons.
Press and release the Advance (Front) button to display the first 2 digits of the KEY CODE, flash-
ing as 00.
Press and release the Select (Bottom) button to increase the digits to 01.
Press and release the Advance (Front) button again to display the second 2 digits of the KEY
CODE, flashing as 00.
Press and release the Select (Bottom) button to increase the digits to 01.
Press and release the Advance (Front) button to complete the RESET operation and turn the unit
OFF.