Specifications
28
TO SET - MAX DEPTH ALARM (while in the Surface Mode)
Factory set for 330 feet, the Maximum Depth Alarm can be set to
values between 30 feet (9 meters) and 330 feet ( 99 meters) in incre-
ments of 10 foot (3 meters).
Press Both buttons simultaneously, release when SET: 1 appears.
Press and release the Advance (Front) button, FO2 appears with
the value flashing.
Press the Advance (Front) button 1 more time.
The graphics MAX FEET (or M) and dEEP, and Alarm icon ap-
pear with the Max Depth value flashing (Fig. 20).
Press and release the Select (Bottom) button until the desired
Alarm value appears, or press and hold to scroll through the set
points.
Press the Advance (Front) button to accept the setting and ad-
vance to Elapsed Dive Time Alarm, or press and hold Both but-
tons for 2 seconds to revert to Surface Mode.
The unit reverts to Surface Mode after 2 minutes if neither button
is pressed.
Fig. 20 - Set Depth Alarm