Specifications
38
TO SET - END PRESSURE ALARM
(while in the Surface Mode)
Factory set for 00 PSI/BAR (disabled), the End Pressure Alarm can
be set to values between 300 and 1500 PSI (20 to 104 BAR) in in-
crements of 100 PSI (7 BAR).
Press Both buttons simultaneously, release when SET: 2 appears
(4 seconds).
Press and release the Advance (Front) button, the Units screen ap-
pears with the set point flashing.
Press the Advance (Front) button 10 more times.
The graphic End and Alarm (speaker) icon appear with the End
Pressure Alarm value flashing (Fig. 33).
Press and hold the Select (Bottom) button to scroll through the
Alarm values.
Press the Advance (Front) button to accept the setting and ad-
vance to Set Dive Time Remaining Alarm, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
Fig. 33 - Set End Pressure Alarm