If you descend below the required decompression ceiling before 5 minutes have elapsed, the ATMOS
ai
will continue to function in Decompression Dive Mode. In this case, no off-gassing credit will be
given, and for each minute above the ceiling 1
1
/
2
minutes of Penalty Time will be added to Required
Stop Time.
The added Penalty (decompression) Time will have to be 'worked off' first, before obtaining off-gas-
sing credit.
Once the Penalty Time is worked-off, and off-gassing credit begins, required decompression Stop
Depths and Time will decrease toward zero, then the Nitrogen Bar Graph will recede into the yellow
Caution Zone and the ATMOS
ai
will revert to the No Decompression Dive Mode.
NOTE: Upon entry into Delayed Violation Modes, the Audible Alarm will sound
for 10 seconds, even if it is user Set OFF. It cannot be turned off (acknowl-
edged) by pressing the Advance (Front) button.
Delayed Violation Mode #1 (Fig. 54)
If you remain above the Required Ceiling Stop Depth for 'more
than 5 minutes', the Nitrogen Bar Graph and Total Ascent Time
display will flash until you descend below the Required Stop Depth.
This is a continuation of a Conditional Violation.
Fig. 54 - Delayed Violation #1
Full BG Flashing