Technical data
28
A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
•  Dive Computer (Air or Nitrox up to 50% O2). 
•  Dual Algorithm >> Buhlmann ZHL-16c based Pelagic Z+, or DSAT based.
•  No Deco limits >> closely follow PADI RDP.
•  Decompression >> in agreement with Buhlmann ZHL-16c and French MN90.
•  Altitude >> Buhlmann, IANTD, RDP (Cross).
•  Altitude corrections and O2 limits >> based on NOAA tables. 
  Accuracy:
•  Depth  ±1% of full scale
•  Timers  1 second per day
• Must rst be activated by button press.
• Automatic activation of Dive Mode by immersion in water.
• Cannot be manually activated deeper than 4 FT (1.2 M).
• Cannot operate at elevations higher than 14,000 feet (4,270 meters).
• 2 hours after activation, if no dive conducted.
• 24 hours after conducting a dive, if no further dives conducted.
•  Displays Dives #1 to 12. 
•  Resets to Dive #1, upon diving (after 24 hours with no dives).
•  Stores 12 most recent dives in memory for viewing.
•  After 12 dives, adds 13th dive in memory and deletes the older dive.
•  Operational from sea level to 14,000 feet (4,270 meters) elevation.
•  Measures ambient pressure upon activation and every 15 minutes while in Surface modes.
•  Does not measure ambient pressure when Wet.
•  Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
• Battery  (1) 3 vdc, CR2450, Lithium battery (Panasonic or equivalent).
• Shelf life  Up to 5 years.
• Replacement  User replaceable (annual recommended).
• Use Life  1 year or 300 dive hours if (2) 1 hour dives per dive day.
 
•  Warning >> icon on solid when <= 2.75 volts, Battery change recommended.
•  Alarm >> icon on ashing when <= 2.50 volts, change the Battery, will not function. 
•  Full functions >> to 330 FT (100 M).
•  Watertight >> to 495 FT (150 M). 
•  Out of the water >> between 20 °F and 140 °F (- 6 °C and 60 °C).
•  In the water >> between 28 °F and 95 °F (- 2 °C and 35 °C). 
SPECIFICATIONS