Technical data
29
A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
            segments   
• No Deco Normal zone (green)     1 to 13 = 5 to 65% allowable tissue loading.           
• No Deco Caution zone (yellow)    14 to 19 = 70 to 95% allowable tissue loading.         
• Decompression zone (red)        20 = 100% tissue loading.   
    60 FT (18 M) & Shallower          Deeper than 60 FT (18 M)     
      segments   FPM     MPM        segments   FPM  MPM
        0        0 - 10    0 - 3          0      0 - 20  0 - 6 
•  Normal zone (green)      1        11 - 15   3.5 - 4.5        1        21 - 30  6.5 - 9
  Normal zone (green)      2      16 - 20  5 - 6          2      31 - 40  9.5 - 12
  Normal zone (green)      3      21 - 25  6.5 - 7.5        3      41 - 50  12.5 - 15
•  Caution zone (yellow)      4        26 - 30  8 - 9          4        51 - 60  15.5 - 18
•  Too Fast zone (red)    5 (all)  > 30   > 9   5 (all) > 60  > 18 
 Range:    Resolution:
•  Altitude Level  Sea, L2 to L7    1 (level)
•  Time to Fly  23:50 to 0:00 hr:min    1 minute
•  Time to Desaturate  23:50 to 0:00 hr:min    1 minute
•  Temperature  0 to 99°F (-18 to 60°C)    1°F (C)
•  Depth  0 to 330 FT (100 M)    1 FT (0.1 M )   
•  Surface Interval Time  0:00 to 23:59 hr:min    1 minute
•  Dive Number  0 to 12    1 (dive) 
•  EDT  0 to 9:59 hr:min    1 minute
•  DTR  0 to 9:59 hr:min    1 minute
•  FO2  Air, 21 to 50 %    1 %
•  PO2  0.00 to 5.00 ATA    .01 ATA
•  O2  0 to 100 %    1 %
•  Safety Stop Time  3:00 to 0:00 min:sec    1 second
•  Deco Stop Time  0:00 to 9:59 hr:min    1 minute
•  Deco Total Ascent Time  0:00 to 9:59 hr:min    1 minute
•  Violation Countdown Timer  23:50 to 0:00 hr:min    1 minute
SPECIFICATIONS (CONTINUED)










