Specifications

TOXICS
9/01/2008 52-1002-5 Toxics Gas C.4
C706X Electrochemical Sensor Housings (sensor cell sold separately)
Model Part Number Toxic Gas
Enclosure
Threads
Enclosure
Material
Measurement
Range
Appro vals Other
C7064C4012* 004539-004 Hydrogen Sulfide 3/4 NPT SS All CSA IS
C7064E4012 004539-00 9 Hydrogen Sulfide 3/4 NPT SS All FM/CSA/ATEX/CE Groups C , D
C7064C5014* 004539-01 4 Hydrogen Sulfide M20 SS All CSA IS
C7064E5012 004539-10 2 Hydrogen Sulfide M20 SS All FM/CSA/ATEX/CE
C7064E6031 004539-10 3 Hydrogen Sulfide M20 SS All CSA/ATEX/CE
C7064E6012 004539-104 Hydrogen Sulfide 3/4 NPT SS All C SA/ATEX/CE CEPEL
C7064E5014 004539-105 Hydrogen Sulfide 3/4 NPT SS All FM/CSA/ATEX/CE Grou ps B, C, D
C7067E7012* 005 931-001 Chlorine 3 /4 NPT AL 0-10 ppm CSA IS
C7067E7031* 005 931-002 Chlorine M20 AL 0-10 ppm CSA IS
C7066E6012 005736-001 Carbon Monoxide 3/4 NPT AL 0-100 ppm CSA
C7066E6031 005736-002 Carbon Monoxide M20 AL 0-10 0 ppm CSA
C7066E7012 005736-003 Carbon Monoxide 3/4 NPT AL 0-500 ppm CSA
C7066E7031 005736-004 Carbon Monoxide M20 AL 0-50 0 ppm CSA
C7066E8012 005736-005 Carbon Monoxide 3/4 NPT AL 0-1000 ppm CSA
C7066E8031 005736-006 Carbon Monoxide M20 AL 0-1000ppm CSA
C7068E8012 006398-00 1 Sulfur Dioxide 3/4 NPT SS 0-100 ppm CSA
C7068E8031 006398-00 2 Sulfur Dioxide M20 SS 0-100 ppm CSA
C7065E5012 005723-001 Oxygen 3/4 NPT AL 0-25% v/v CSA
C7065E5031 005723-00 2 Oxygen M20 AL 0-25% v/v CSA
* These gas detectors are intrinsically-safe only when used with appropriate transmitter or external IS barrier. For use with U8800/U8810 only.
NOTE: All C706x housings above require an electrochemical sensor cell (not included) for proper operation.
Shipping weight of all C706x gas detector housings is 2.5 lb (1.28 kg).