Manual

Model PI-700 0-500ppb
PI-700 0-500ppb Instruction Manual Rev. 0.0 Page 49 of 53
Compound Name Synonym/Abbreviation Formula
Response
Factor
1
Confirmed
Value
IP (eV) TWA
Tetramethyl orthosilicate Methyl silicate, TMOS C4H12O4Si 1.9 + ~10 1
Therminol VP-1
Dowthern,3:1 Diphenyl oxide:
Biphenyl
C12H10O
C12H10
0.7 + ne
Toluene Methylbenzene C7H8 0.50 + 8.82 50
Tolylene-2,4-diisocyanate
TDI, 4-Methyl-1,3-phenylene-
2,4- diisocyanate
C9H6N2O2 1.4 + 0.002
Trichlorobenzene, 1,2,4- 1,2,4-TCB C6H3Cl3 0.46 + 9.04 C5
Trichloroethane, 1,1,1- 1,1,1-TCA, Methyl chloroform C2H3Cl3 NR + 11 350
Trichloroethane, 1,1,2- 1,1,2-TCA C2H3Cl3 NR + 11.0 10
Trichloroethene TCE, Trichloroethylene C2HCl3 0.54 + 9.47 50
Trichlorotrifluoroethane,
1,1,2- CFC-113
C2Cl3F3 NR 11.99 1000
Triethylamine TEA C6H15N 0.9 + 7.3 1
Triethyl borate
TEB; Boric acid triethyl ester,
Boron ethoxide
C6H15O3B 2.2 + ~10
Triethyl phosphate Ethyl phosphate C6H15O4P 3.1 + 9.79 ne
Trifluoroethane, 1,1,2-
Trimethylamine
C2H3F3 NR 12.9 ne
Trimethylbenzene, 1,3,5-
(see Mesitylene)
C3H9N 0.9 7.82 5
Trimethyl borate
TMB; Boric acid trimethyl ester,
Boron methoxide
C3H9O3B 5.1 + 10.10 ne
Trimethyl phosphate Ethyl phosphate C3H9O4P 8.0 + 9.99 ne
Turpentine Pinenes (85%) + other diisoprenes C10H16 0.3 + ~8 100
Undecane C11H24 2 9.56 ne
Varsol (see Mineral Spirits)
Vinyl actetate C4H6O2 1.2 + 9.19 10
Vinyl bromide Bromoethylene C2H3Br 0.4 9.80 5
Vinyl chloride in N2 Chloroethylene, VCM C2H3Cl 2.0 + 9.99 5
Vinylidene chloride
(see 1,1-Dicholorethene)
Vinyl-2-pyrrolidinone, 1-
NVP, N-vinylpyrrolidone, 1-
ethenyl-2-pyrrolidinone
C6H9NO 0.8 + ne
Viscor 120B – (see Mineral
Spirits - Viscor 120B
Calibration Fluid)
Xylene, m- C8H10 0.4 + 8.56
Xylene, o- C8H10 0.6 + 8.56
Xylene, p- C8H10 0.5 + 8.44
NR = not recommended (does not register)
? = measurable but no data exists
Confirmed Value = “+” means actual gas has been used to verify RF, “blank” means it is an empirical estimate
IP = is the gases ionization potential (only gases < 10.6eV will respond to sensor)
TWA/Time Weighted Average = generally accepted limit for safe 8 hour exposure (in ppm)
ne = None established
9.3 Spare Parts, Sensor Accessories, Calibration Equipment