Product Manual

34
Depending on the version of WinDDE, the Setup Indicators window should look similar to the screenshot below.
Choose the correct Device Port and ensure that the communications setting are correct and press OK.
210PRINT Permits print capture of gross, tare, and net weight.
210 Setup
1. Press “*”. The display will show “Funct=”. Press “REVIEW”.
2. The display will show “PUO=” Press “ENTER”. The display will show “no”. Press “ENTER.”
2. The display will show “td=” Press “ENTER”. The display will show “12”. Press “ENTER.”
2. The display will show “d oUt=” Press “ENTER”. The display will show “0”. Press “ENTER.”
3. The display will show “SLEEP=”. Press “ENTER”. The display will show the sleep value. Press
“ENTER”.
4. The display will show “A off=”. Press “ENTER”. The display will show the auto-off setting. Press
“ENTER”.
5. The display will show “CLTar=” Press “ENTER”. The display will show the clear-tare setting. Press
“ENTER”.
6. The display will show “Sio?” Press “ENTER”. The display will show “no”. Press the “1/YES” key to
change the display to “YES”. Press “ENTER”.
7. The display will show “bAUd=” Press “ENTER”. The display will show the current baud rate setting. For
the default 9600 baud press the “9” and “6” key so that the display shows “96”. Press “ENTER”.
8. The display will show “PrtY=” Press “ENTER”. The display will show the current parity setting. For the
default no parity press the “0” key so that the display shows “0”. Press “ENTER”.
9. The display will show “BitS=” Press “ENTER”. The display will show the current data bits setting. For the
default eight data bits press the “8” key so that the display shows “8”. Press “ENTER”.
10. The display will show “StoP=” Press “ENTER”. The display will show the current stop bits setting. For
the default one stop bit press the “1” key so that the display shows “1”. Press “ENTER”.
11. The display will show “Cont1=” Press “ENTER”. The display will show the current setting for
continuous data for serial port one. For printer capture the indicator must not be continuous. Press the
“0/NO” key so that the display shows “no”. Press “ENTER”.