Product Manual

35
12. The display will show “Cont2=” Press “ENTER”. The display will show the current setting for
continuous data for serial port two. For printer capture the indicator must not be continuous. Press the
“0/NO” key so that the display shows “no”. Press “ENTER”.
13. The display will show “Print?”. Press “ENTER”. The display will show “no”. Press the “1/YES” key to
change the display to “YES”. Press “ENTER”.
14. The display will show “Port=”. Press “ENTER”. The display will show the serial port selected for printer
output. Press the “1” or “2” key to set this to the correct port to be connected to the computer. If only one
serial port is wired from the 210 indicator this would usually be “1”. Press “ENTER”.
16. The display will show “HoUr=”. Press “ENTER”. The display will show the current tab setting for the
time. Press the “0” key to change the to “0.00” so that the time is not provided in the output. Press
“ENTER”.
17. The display will show “dAte=”. Press “ENTER”. The display will show the current tab setting for the
date. Press the “0” key to change the display to “0.00” so that the date is not provided in the output. Press
“ENTER”.
18. The display will show “CnC n=”. Press “ENTER”. The display will show the current tab setting for the
consecutive number. Press the “0 key to change the display to “0.00” so that the consecutive number is
provided on the sixth line of the output. Press “ENTER”.
19. The display will show “GroSS=”. Press “ENTER”. The display will show the current tab setting for the
gross weight. Press the “2”, “0”, and then the “1” key to change the display to “2.01” so that the gross
weight is provided on the second line of the output. Press “ENTER”.
20. The display will show “tArE=”. Press “ENTER”. The display will show the current tab setting for the tare
weight. Press the “3”, “0”, and then the “1” key to change the display to “3.01” so that the tare weight is
provided on the third line of the output. Press “ENTER”.
21. The display will show “nET=”. Press “ENTER”. The display will show the current tab setting for the net
weight. Press the “4”, “0”, and then the “1” key to change the display to “4.01” so that the net weight is
provided on the fourth line of the output. Press “ENTER”.
22. The display will show “G ACC=”. Press “ENTER”. The display will show the current tab setting for the
gross accumulator. Press the “0” key to change display to “0.00” sot that the gross weight accumulator is
not provided on the output. Press “ENTER”.
23. The display will show “n ACC=”. Press “ENTER”. The display will show the current tab setting for the
net accumulator. Press the “0” key to change the display to “0.00” so the net weight accumulator is not
provided on the output. Press “ENTER”.
24. The display will show “CoUnt=”. Press “ENTER”. The display will show the current tab setting for the
count. Press the “0” key to change the display to “0.00” so the count is not provided on the output. Press
“ENTER”.
25. The display will show “EACH=”. Press “ENTER”. The display will show the current tab setting for the
each. Press the “0” key to change the display to “0.00” so the each value is not provided on the output.
Press “ENTER”.
26. The display will show “CrLF=”. Press “ENTER”. The display will show the current setting for carriage
return line feed. Press the “1/YES” key so that the display shows “YES”. Press “ENTER”.
27. The display will show “EoP=”. Press “ENTER”. The display will show the current setting for end of
print. Press the “0” key so that the display shows “0”. Press “ENTER”.