THE DIGISHOT
®
PLUS BASE STATION SHOULD NEVER BE CONNECTED TO THE DIGISHOT
®
PLUS
DETONATORS OR THE LEAD-IN HARNESS WIRE, AND ESPECIALLY WHILST THE DIGISHOT
®
PLUS BASE
STATION IS CONNECTED TO A DIGISHOT
®
CHARGER.
Switch off the DigiShot
®
Plus Base Station.
Connect charger to DigiShot
®
Plus Base Station
Connect DigiShot
®
Plus charger to a 220VAC
power supply
Charge for at least 6 hours
To test the Base Station battery:
o Switch On Base Station and allow the
battery levels to stabilize. Take reading
after 2 minutes and leave the Base
Station On for 20 minutes then take
another reading. Compare the voltage
percentage drop. If the voltage dropped
by 10% or more it indicates that the
battery is faulty and needs to be replaced.
o Alternatively the Base Station can be switched On for 5 10 minutes and the voltage
reading taken. Perform a dummy blast and then compare the reading to determine if the
voltage dropped by 10% or more which will indicate that the battery is faulty and needs to
be replaced.
Displayed messages related to low battery state
When the battery drops below 45% the Battery Low message is
displayed in certain states.
The warning check is performed at the start of programming and
arming only.
When the battery drops to 0%, the Battery Low message appears
and the Base Station switches off immediately afterwards.
WARNING BATTERY LOW
BAT LEVEL 17%
ENTER TO ACCEPT
BATTERY LOW .
TURNING OFF