Specifications
Table Of Contents
- 1. USERS OF THIS MANUAL
- 2. SYSTEM PRODUCT SAFETY
- 3. Warning, Caution, and Note Statements
- 4. DigiShot® Plus Base Station
- 4.1. Components
- 5. Base Station Accessories
- 5.1. RF Antennae
- 6. Setup and Configuring DigiShot® Plus Base Station
- 6.1. Charging the DigiShot® Plus Base Station
- 6.2. Battery Errors
- 6.3. Power Base Station On
- 6.4. Power OFF DigiShot® Plus Base Station
- 6.5. Menu Navigation
- 7. System Settings
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 3. Under System Settings
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 9. Operation
- 9.1. Testing and Programming Detonators
- 9.2. Reprogramming Bench Box(es)
- 9.3. Blast RF Mode
- 9.4. Exit the blast sequence without firing (disarming)
- 9.5. Permanent Abort
- 9.6. Programming Errors before Arming
- 9.7. High Leakage during Arming
- 9.8. Last Det Check
- 9.9. Synchronisation Errors
- 10. Specifications
- 11. Troubleshooting Error Codes
- 12. Blast Layout
- 12.1. Unsynchronised Multiple Bench Box Blasting
- 12.2. Synchronised Multiple Bench Box Blasting
UTM-00232 | Rev 9
DetNet South Africa Copyright © 2018
Page 11 of 51
THE DIGISHOT
®
PLUS BASE STATION SHOULD NEVER BE CONNECTED TO THE DIGISHOT
®
PLUS
DETONATORS OR THE LEAD-IN HARNESS WIRE, AND ESPECIALLY WHILST THE DIGISHOT
®
PLUS BASE
STATION IS CONNECTED TO A DIGISHOT
®
CHARGER.
Switch off the DigiShot
®
Plus Base Station.
• Connect charger to DigiShot
®
Plus Base Station
• Connect DigiShot
®
Plus charger to a 220VAC
power supply
• Charge for at least 6 hours
• To test the Base Station battery:
o Switch On Base Station and allow the
battery levels to stabilize. Take reading
after 2 minutes and leave the Base
Station On for 20 minutes then take
another reading. Compare the voltage
percentage drop. If the voltage dropped
by 10% or more it indicates that the
battery is faulty and needs to be replaced.
o Alternatively the Base Station can be switched On for 5 – 10 minutes and the voltage
reading taken. Perform a dummy blast and then compare the reading to determine if the
voltage dropped by 10% or more which will indicate that the battery is faulty and needs to
be replaced.
Displayed messages related to low battery state
When the battery drops below 45% the Battery Low message is
displayed in certain states.
The warning check is performed at the start of programming and
arming only.
When the battery drops to 0%, the Battery Low message appears
and the Base Station switches off immediately afterwards.
WARNING BATTERY LOW
BAT LEVEL 17%
ENTER TO ACCEPT
BATTERY LOW .
TURNING OFF