Specifications
Table Of Contents
- 1. USERS OF THIS MANUAL
- 2. SYSTEM PRODUCT SAFETY
- 3. Warning, Caution, and Note Statements
- 4. DigiShot® Plus Base Station
- 4.1. Components
- 5. Base Station Accessories
- 5.1. RF Antennae
- 6. Setup and Configuring DigiShot® Plus Base Station
- 6.1. Charging the DigiShot® Plus Base Station
- 6.2. Battery Errors
- 6.3. Power Base Station On
- 6.4. Power OFF DigiShot® Plus Base Station
- 6.5. Menu Navigation
- 7. System Settings
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 3. Under System Settings
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 9. Operation
- 9.1. Testing and Programming Detonators
- 9.2. Reprogramming Bench Box(es)
- 9.3. Blast RF Mode
- 9.4. Exit the blast sequence without firing (disarming)
- 9.5. Permanent Abort
- 9.6. Programming Errors before Arming
- 9.7. High Leakage during Arming
- 9.8. Last Det Check
- 9.9. Synchronisation Errors
- 10. Specifications
- 11. Troubleshooting Error Codes
- 12. Blast Layout
- 12.1. Unsynchronised Multiple Bench Box Blasting
- 12.2. Synchronised Multiple Bench Box Blasting
UTM-00232 | Rev 9
DetNet South Africa Copyright © 2018
Page 26 of 51
This function enables the user to set the RF Channel applicable to the specific region. The DigiShot
®
Plus
Bench Box and Base Station need to be set on the same RF Channel in order to communicate.
3. Under Comms Setting
• Press 2 on the keypad to select SET RF CHANNEL.
4. Under Channel Setup Menu
• Press 1 on the keypad to SET CHANNEL
5. Set RF Channel
• Use numerical keys to enter RF Channel.
• Press ENTER to confirm.
• Press ESC to exit.
SET CHANNE 1 - 7
RF CHANNEL? 7
COMMS SETTINGS
1. COMMUNICATION LINK
2. SET RF CHANNEL
3. SET RF KEY
CHANNEL SETUP MENU
1. SET CHANNEL
2. SET REPEATER CHANNEL