Specifications

UTM-00232 | Rev 9
DetNet South Africa Copyright © 2018
Page 31 of 51
1. Remote Status Screen
The following columns are displayed:
ID Bench Box number and current connection status
Dets Number of detonators connected to Bench Box
Mode Powered, detonators are powered
RF - Communication Level Ratio of messages received to
messages sent expressed as a percentage. Minimum acceptable
level of 75 percent, anything below 60 percent could result in
communication problems between boxes when attempting a
synchronised blast.
E Errors detected Y(es) or N(o)
ID DETS MODE RF E
1 0 UNKNOWN N
2 0 UNKNOWN 0 N
3 0 UNKNOWN N
4 21 POWERED 10 N
TIME LEFT: 00:00:00
PRESS (1-4) FOR DETAIL
PRESS ESC TO CHANGE MENU
BAT LEVEL: 100%
BOX 4 -CONNECTED
DETCOUNT: 21
STATUS: POWERED
PROG ERROR: 0
CURRENT LIM:
BACK SCAN: OK
BOUNDARY CHECK: OK
VOLTAGE: 7V
LEAKAGE: 1.07mA
CURRENT: 1.49mA
CHANNEL: 1 2 3 4 5 6
HARNESS ERR - - - - - -
PAGE 2
BOX 4 -CONNECTED
REMOTE KEY: DISABLED
GRACE: -
UPCONV OUT: 6V
BATTERY OUT: 89%
INTERLOCKS: OFF OFF OFF
PAGE 1
BOX 4 -CONNECTED
REMOTE KEY: PRESENT
GRACE: 00:01:53
UPCONV OUT: 6V
BATTERY: 89%
INTERLOCKS: OFF OFF OFF
PAGE 1