Main Screen during Programming of detonators
Programming is completed at the Bench Box.
After programming all detonators, a background scan starts scanning all programmed detonators to
ensure that states of all programmed detonators remain unchanged. Should any detonator state change,
an error will be displayed. This is indicated by BACK SCAN in the display.
Refer to Troubleshooting Error codes for causes and recommended remedial action.
BOX 4 CONNECTED
DETCOUNT: 200
STATUS: PROGRAM 57%
PROG ERROR: 0
CURRENT LIM: 2
BACK SCAN: OK
BOUNDARY CHECK:OK
VOLTAGE: 7V
LEAKAGE: 0.05mA
CURRENT: 0.11mA
CHANNEL 1 2 3 4 5 6
HARNESS ERR - - X - - -
PAGE 2 >
ID DETS MODE RF E
1 0 UNKNOWN N
2 200 PROGRAMMING 89 Y
3 0 UNKNOWN N
4 0 UNKNOWN N
TIME LEFT: 00:59:15
PRESS (1-4) FOR DETAIL
PRESS ESC TO CHANGE MENU
BAT LEVEL: 100%
BOX 4 CONNECTED
REMOTE KEY: DISABLED
GRACE: -
UPCONV OUT: 6V
BATTERY: 89%
INTERLOCKS: OFF OFF OFF
< PAGE 1