Specifications
Table Of Contents
- 1. USERS OF THIS MANUAL
- 2. SYSTEM PRODUCT SAFETY
- 3. Warning, Caution, and Note Statements
- 4. DigiShot® Plus Base Station
- 4.1. Components
- 5. Base Station Accessories
- 5.1. RF Antennae
- 6. Setup and Configuring DigiShot® Plus Base Station
- 6.1. Charging the DigiShot® Plus Base Station
- 6.2. Battery Errors
- 6.3. Power Base Station On
- 6.4. Power OFF DigiShot® Plus Base Station
- 6.5. Menu Navigation
- 7. System Settings
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 3. Under System Settings
- 1. Display Remote Status Screen
- 1. Display Remote Status Screen
- 9. Operation
- 9.1. Testing and Programming Detonators
- 9.2. Reprogramming Bench Box(es)
- 9.3. Blast RF Mode
- 9.4. Exit the blast sequence without firing (disarming)
- 9.5. Permanent Abort
- 9.6. Programming Errors before Arming
- 9.7. High Leakage during Arming
- 9.8. Last Det Check
- 9.9. Synchronisation Errors
- 10. Specifications
- 11. Troubleshooting Error Codes
- 12. Blast Layout
- 12.1. Unsynchronised Multiple Bench Box Blasting
- 12.2. Synchronised Multiple Bench Box Blasting
UTM-00232 | Rev 9
DetNet South Africa Copyright © 2018
Page 33 of 51
Main Screen during Programming of detonators
Programming is completed at the Bench Box.
After programming all detonators, a background scan starts scanning all programmed detonators to
ensure that states of all programmed detonators remain unchanged. Should any detonator state change,
an error will be displayed. This is indicated by BACK SCAN in the display.
Refer to Troubleshooting Error codes for causes and recommended remedial action.
BOX 4 CONNECTED
DETCOUNT: 200
STATUS: PROGRAM 57%
PROG ERROR: 0
CURRENT LIM: 2
BACK SCAN: OK
BOUNDARY CHECK:OK
VOLTAGE: 7V
LEAKAGE: 0.05mA
CURRENT: 0.11mA
CHANNEL 1 2 3 4 5 6
HARNESS ERR - - X - - -
PAGE 2 >
ID DETS MODE RF E
1 0 UNKNOWN N
2 200 PROGRAMMING 89 Y
3 0 UNKNOWN N
4 0 UNKNOWN N
TIME LEFT: 00:59:15
PRESS (1-4) FOR DETAIL
PRESS ESC TO CHANGE MENU
BAT LEVEL: 100%
BOX 4 CONNECTED
REMOTE KEY: DISABLED
GRACE: -
UPCONV OUT: 6V
BATTERY: 89%
INTERLOCKS: OFF OFF OFF
< PAGE 1