Specifications

UTM-00232 | Rev 9
DetNet South Africa Copyright © 2018
Page 35 of 51
Blasting in a RF mode enables the user to blast from a DigiShot
®
Plus Base Station using a radio
frequency wireless link to the DigiShot
®
Plus Bench Box.
The minimum re-entry period is ten minutes after disconnecting the lead in wires.
The mine or local legal procedures for the blasting at the designated site must be adhered to.
These site-specific rules must be referred to before re-entry!
Display Remote Status Screen
Mode indicates Grace period countdown
Grace period time to allow all personnel to move to a point
of safety before the voltage is allowed to be raised.
The RF signal strength should be as high as possible to avoid
communication issues (the figure is calculated on % of recent
successful messages).
For synchronised blasting it is recommended that the
communication percentage be above 75%. Communication levels
below this value could result in synchronisation failures during
blasting.
Ready to Arm DigiShot
®
Plus Bench Box automatically shuts down
after approximately 60 minutes (minimum 50 minutes and maximum
70 minutes), after the Smart Key is inserted, if no fire command is
issued from the DigiShot
®
Plus Base Station
Mode indicates Base Station is ready to arm
Press ARM soft key to arm the blast
User may be required to reprogram the Bench Boxes. Reprogramming the detonators should preferably be
done under the following circumstances:
Reprogramming is strongly recommended when the system has been armed and disarmed for longer
than 15 minutes.
ID DETS MODE RF E
1 0 UNKNOWN N
2 99 GRACE 00:36 80 N
3 0 UNKNOWN N
4 0 UNKNOWN N
TIME LEFT: 00:55:47
PRESS (1-4) FOR DETAIL
PRESS ESC TO CHANGE MENU
BAT LEVEL 100%
ID DETS MODE RF E
1 0 UNKNOWN N
2 99 READY TO ARM 80 N
3 0 UNKNOWN N
4 0 UNKNOWN N
TIME LEFT: 00:53:15
PRESS (1-4) FOR DETAIL
PRESS ESC TO CHANGE MENU
BAT LEVEL: 100%
. PROGRM ARM .