ERROR
CAUSES OF ERRORS
REMEDIAL ACTIONS
E25: ERROR:
RESPONSE
MISMATCH
User is trying to access a protected
function
Contact local supplier
E26: YOU MAY GET
MISFIRES
Untagged detonators found or the
current limiter has been reached.
Find and fix the untagged detonators
or resolve the current issue. See
E19.
E27: KEYS DON’T
MATCH
The Smart Key inserted into the Base
Station and Bench Box are not part
of a matching pair of Smart Keys
Only use matching pairs of Smart key
E28: WRONG STATE
TO PROGRAM
Not implemented in current software
version
E29: NOT
PROGRAMMED YET
Arming or firing a blast before
programming
Program the blast first
E30: NOT READY TO
ARM YET
Attempting to arm the Base Station
when Bench Box is not out of the
grace period yet
Wait for the grace period to finish
E31: INTERNAL STATE
ERROR
Internal error Return Bench Box for repair
E32: POWERLOCK
ERROR
Internal error Return Bench Box for repair
E33: UNEXPECTED
DET TIME
Not implemented in current software
version
E34: DUPLICATE DET
FOUND
You have two detonators in the
detonator list with the same location
Remove one of the duplicates.
Confirm deletion against Taggers
detonator list and blast plan
E35: BACKGROUND
SCAN ERROR
After programming, the Bench Box
continues to communicate with all
detonators that were successfully
programmed. If communication fails,
then something has gone wrong e.g.
wires removed, shorted, detonator
faulty etc.
Try reprogramming to see which
detonator is at fault and then debug
as normal for programming errors.
Check wiring for shorts, intermittence
etc. before doing so.
E36: NOT
IMPLEMENTED YET
Trying to use a feature that is not
implemented in the version of
software being used.
The feature may be available in
future software updates
E37: WRONG KEY
COLOUR
Incorrect colour Smart Key inserted Remove Smart Key. Press a button
and insert the correct key