Specifications

UTM-00232 | Rev 9
DetNet South Africa Copyright © 2018
Page 49 of 51
ABORT FAILURE
MESSAGE
PROBABLE CAUSE SUGGESTED ACTION
ABORT PRESSED
User pressed abort The box aborted as requested. Turn
off and on to start over
POWERLOCK ADC
ERROR
Internal error has occurred Return Base Station for repair
KEY NOT EXPECTED
Smart Key inserted at the wrong time
Only insert the Smart Key when
prompted. Remove Smart Key, switch
off Base Station to reset.
Switch Base Station on
RELAY ERROR
Internal error has occurred
Return Base Station for repair
IO VOLTAGE
The voltage on the IO channel outputs
is higher than expected. There may
be an external voltage source
connected or the box may have a fault
Return Base Station for repair
REMOTE ABORT
Does not apply to the Base Station Does not apply to the Base Station
CHARGER INSERTED
You inserted a charger while the box
was on.
The Base Station should be off and
disconnected from any detonators
when it is connected to a charger
I2C FAILURE
Internal error has occurred
Return Base Station for repair
TIMER FAILURE
Internal error has occurred
Return Base Station for repair
POWERLOCK
SHUTDOWN
Internal error has occurred Turn the box off, wait a few seconds,
turn the box on again. If the problem
persists, return the box to the supplier
for repair.
COMMUNICATION
SPEED ERROR
Internal error has occurred Return Base Station for repair
BOX MODE CORRUPT
See E45
UNKNOWN
See E40