Connect up to four different benches with sequential timing across all connected Bench Boxes.
Detonator timing is set as one bench, connected to up to four Bench Boxes.
When splitting the bench onto multiple Bench Boxes, take into consideration:
o system limits,
o leakage
o and the load required to fire all Bench Boxes successfully.
All Bench Boxes will receive the fire command at the same time.
Should one Bench Box fail before the blast is initiated, the problematic Bench Box will send a
message to the Base Station and return to a rearming state. The Base Station will stop the entire
blast.
The user may attempt re-blasting after improving the communication strength to the Bench Boxes.
It is recommended that RF communication strength be greater than 75%, with the minimum of 60%, for all
Bench Boxes when attempting a synchronised blast this figure is displayed on the Base Station.