This function supports the use of NetShock / DriftShot Starter detonators, which will allow the user to interface
to Shocktube / Nonel. To enable this function the user must select ‘Use Starter dets’ in the DigiShot Setup
menu shown below.
1. Main Menu
Press to select Configuration
2. Configuration Menu
Press to select DigiShot Setup
3. DigiShot
®
Setup
Press to select Use Starter dets
4. Use Starter Dets.
Use the arrow key to display the YES /NO option
as required.
Press to continue
Press Soft Key to save and Soft Key to return
to Main Menu
When the ‘Use Starter dets’ feature is activated, the Tagger will scan for Starter
detonators in the Test Single Detonator, Test All, Autosearch and Check Pattern