Ensure DigiShot
®
Plus detonator connector is pushed down properly on the Pogo pin
connector before tagging detonators.
The first step in the tagging process, regardless of the mode (AUTO-TAG or SINGLE) is measuring of leakage.
Should the leakage be greater than 0.50mA, a leakage warning will be displayed.
Tagger vibrates to inform the user of an error condition.
Press to continue or ESC to abort tagging.
While the tagger waits for user-input, other key presses are ignored, as the user
must respond to the indicated problem with ENTER or ESCAPE.
On completion of the tagging process a message is displayed indicating the success or failure of the operation.
The possible failed messages could be any of the following:
a. Leakage too high- Tagger could not obtain a good det reply possibly due to
the excessively high leakage detected.
b. Possibly many dets- Possibly more than one det connected. Only one det
must be connected at a time.
c. No det reply” – No detonator reply was detected, detonator could possibly be
faulty or not connected.