12. Remote Blast
Wait if message “Not ready yet” is displayed and when
connected to the bench the base will display Grace and
the time left for grace period to elapse
13. User will be prompted to Scan Key once all the bench Rangers are out of grace period
and ready to blast.
14. Scan Key
Scan the RED BlastCard at the back of the DigiShot
®
Ranger
Enter the corresponding PIN
Press to continue
Press and Hold the NEXT button on the front of the
DigiShot
®
Ranger for 2 seconds
The DigiShot
®
Ranger will initiate
arming and a 30-second high-
voltage charging period followed
by Testing Line and the 120-
second blast window.
15. To disarm the blast
The user is also provided with an option to Arm the Ranger without the need to connect
the tagger via an AutoArm function. The AutoArm function will allow the user to scan a no
PIN yellow BlastCard and if there are no errors present; program and move to the waiting
for next press state. The user will then have to press next for 2 seconds and the unit will
then be ready to arm.