System Description

UTM-00355 | Rev 2
Page 214 of 261
DetNet South Africa Copyright © 2022
27. Scan Key
Scan the RED BlastCard at the back of the DigiShot
®
Ranger
Enter the corresponding PIN
Press to continue
Press and Hold the NEXT button on the front of the
DigiShot
®
Ranger for 2 seconds
The DigiShot
®
Ranger will initiate arming and a 30-second high-voltage charging
period followed by the 90-second blast window.
28. To disarm the blast
From the Base Ranger press the button
Once all the applicable Bench Rangers are Armed and no fault has been detected then
user can proceed with Synchronized blasting of all Bench Rangers from Base. It is
important that the user ensures good RF communication level between the Base and all
Rangers.
Synchronized blast is performed in instances where the same bench is blasted with 2
Bench Rangers or when delays of adjacent benches will affect each other if the order of
blasting is altered. Also useful when there is a possibility of the rock from one bench
possibly cutting off the harness wire to the other bench during blasting.